Installation

 

 

Please read the catalog carefully before installation. Failure to follow the instructions in the catalog may cause danger or cause unpredictable results such as 

product damage. 

 

Do not connect the panel to the power supply during installation, because of the danger of electric shock or equipment damage, which may cause personal injury 

or damage the electrical circuit. 

 

Please install the control panel on the wall about 1.2 meters above the ground and in a location with good ventilation and circulation. Do not install it in a location 

that is directly exposed to heat, damp, dusty or vibrating, so as not to affect the control effect or product life. 

 

The  transmission  distance  between  the  main  communication  network  FCnet  and  the  sub-communication  network  SCnet  is  less  than  300  meters.  It  is 

recommended to use AWG22~24#2C paired copper mesh to isolate and shield the cable. For more than 300 meters, it is recommended to use AWG18~20#2C 

paired copper mesh 

the 

er meter. 

 

The RS485 communication network must adopt a daisy chain connection mode of one input and one output, and it cannot be divergent or star-shaped, and keep 

the positive and negative polarity of the potential consistent. 

 

The  front  and  back  ends  of  the  RS485  communication  network  should  be  equipped  with  120Ω  terminal  resistors  to  effectively  improve  the  stability  of 

communication quality. The total length of the network should not exceed 1,200 meters. 

 

When the group control panel is within 20 meters from the DF.. controller, you can use AWG22~24#4C twisted copper mesh isolation shielded cable to connect 

(two of the cores are used for connecting to the power supply), and the DF.. controller can be used nearby. 5VDC power supply (terminals V+&V-) on the power 

supply;  if  the distance  exceeds 20 meters,  a  5VDC power  supply  must  be  configured  independently.  Remember!  Do not  share  the power  supply  with other 

equipment, so as to avoid the short circuit burnout caused by the difference in circuit design. 

 

FCnet and SCnet communication networks should be covered with EMT metal conduits, and should not be co-managed with power lines or power lines to avoid 

noise interference. 

 

To download the graphic control screen, set the parameters or update the firmware version of the panel, you need to use the computer to run the NFTeditor 

software to operate

Notice! Please unplug the external 5VDC power supply before connecting to the computer

, and then connect it to the computer with a 

Mini USB transmission cable, and use the computer's USB port to directly supply 5VDC, so that the computer and panel information can be transmitted smoothly.

 

 

 

 

   

 

Wall

   

 

Wall

 

22AWG

Twisted pair 
shield cable

MODBUS

Mini

USB

12VDC

M+ M-

V+ V-

BL Y            R  G

 

                    Fig 1Installation 

 

Fig 2 Dismount

 

    Fig 3 NFT28U connection

 

 

Wiring

 

22AWG#4C

Shield cable

MODBUS

Mini

USB

5VDC Power

R B Y G

M+ M-

V+ M+ M- V-

5VDC電源

 

Dimensions

Unit

mm

     

 

風 風

70

12

0

15

19

84

10

9

67

32.5

Ø 5

5

70

 

Please refer t

http://www.airtekgroup.com

 for the most resent update information. 