Airtecnics Kleenbox
46/46 Installation, Operation And Maintenance Manual Download Page 4

TRANSPORT AND STORAGE 

OPERATION INSTRUCTIONS 

WIRING DIAGRAMS 

Fixings 

 

HORIZONTAL 

Four fixing points placed on the four corners: 

 

 
The  moorings  should  be  dimensioned  according  to 
the  weight  of  each  model  (see  technical  data 
section).  The  installation  can  be  done  by  threated 
rods, tensioners or other supports not included. 
 

 

VERTICAL 

Four  wheels  to  make  easier  the  mobility.  Two  of 
them  includes  breaks  which  allow  the  fix  the 
equipment and avoid the undesired displacements. 
  

 

 
 
 
 
 

 

 

Attention! Heavy product. 
Do not stand under the suspended equipment during transport or assembly. 

Store in a dry place protected from the elements. If the packaging is open, cover the purifier to protect it from 
dust.  Do  not  step  on  or  place  heavy  load  son  it  to  avoid  damage  to  he  material.  Storage  temperatura 
between -20ºC and +40ºC. 

When transporting the material, make sure that it is not damaged by the forklift (penetration of the fork in the 
packaging). The instructions on the packaging must be observed. 
 

 

Control board features 

 

ON/OFF:

 Includes a switch which cuts the fan power supply and immediately stops the equipment. 

 

Control 0-100%:

 Includes a 0-10V potentiometer which allows to regulate fan speed from 0 to 100%. 

 

Dirty filter visual alarm: 

by using a led indicator, the equipment informs the user that filters are dirty 

and need to be replaced to keep the air clean. 

 

 

 

 

The following diagrams are attached: 

 

Kleenbox horizontal and vertical. Diagram WELDOE07005 

Summary of Contents for Kleenbox 46/46

Page 1: ...e installation Give this manual to the end user SECURITY ADVISE SYMBOLS WELDOM20110 R0 24 02 21 Attention Danger Safety Warning High voltage or electric current hazard Danger of injury Attention Do no...

Page 2: ...UCTIONS 4 Control board features 4 WIRING DIAGRAMS 4 TECHNICAL DATA 6 MAINTENANCE INSTRUCTIONS 10 Exterior cleaning 10 Internal cleaning 10 REPAIRS AND REEMPLACEMENTS 10 Filter reemplacements 11 Fan r...

Page 3: ...ower and control and necessary fixings are external on the lateral of the equipment The equipment has a service panel to carry out repairs and replacements see REPAIRS section Power supply HORIZONTAL...

Page 4: ...ts If the packaging is open cover the purifier to protect it from dust Do not step on or place heavy load son it to avoid damage to he material Storage temperatura between 20 C and 40 C When transport...

Page 5: ...5...

Page 6: ...6 TECHNICAL DATA...

Page 7: ...7...

Page 8: ...8...

Page 9: ...9...

Page 10: ...t use caustic or acid containing detergents Internal cleaning In models with perforated grille it is advisable to clean the inside of the unit with a vacuum cleaner at least once every 2 years better...

Page 11: ...hey are opened take off the panel using the handle Filter reemplacements Both models include a visual dirty filter alarm When the led is turned ON the H14 HEPA filter must be changed the lifetime of H...

Page 12: ...space to take off the H14 filter This one is fixed to the housing by four wing nuts that should be untighten before remove the filter HEPA H14 Filter To place the filters inside the equipment follow...

Page 13: ...rs to get more working space and avoid damages to them Straightaway disconnect the fan wires Depending on the model we have Kleenbox Horizontal Power supply black box faston 0 10V regulation white box...

Page 14: ...tion It has four hexagonal screws To assemble the new fan follow the same steps in reverse order ACCESSORIES Optional accessories not included for the Kleenbox installation Protection panel for HEPA f...

Page 15: ...15 DECLARATION OF CONFORMITY...

Page 16: ...that eventually suffer failures attributable to production defects Installation costs are borne by the buyer Products that in our opinion have been used improperly handled incorrectly improperly inst...

Reviews: