- CYPRES 2 User’s Guide -
page 53
Data common to Expert, Tandem, Student, Speed, changeable Mode and WSC models:
Length, width, height of the processing unit: ..................................................approx. 85 x 43 x 32 mm
Length, width, height of the control unit: .......................................................approx. 65 x 18 x 6,5 mm
Length, diameter of the release unit: ..........................................................................approx. 43 x 8 mm
Cable length of the release unit (including release unit): ..............................................approx. 500 mm
Storage temperature: ............................................................................................... +71° to -25° Celsius
Storage pressure: ....................................................................200 to 1094 hPa ( 5.906 to 32.306 In.Hg)
Working temperature: ......................................................................................... +63° to -20° Celsius *
Maximum allowable humidity: ......................................................................up to 99,9 % rel. humidity
Waterproof: ......................................................... up to 24 hours down to a depth of 8 feet (2.5 meters)
Dropzone
offset adjustment limits:
....................±3000 feet or ±1000 m (WSC ±1050 feet or ±350 m)
Allowed minimum and maximum altitude .......-2140 feet to +26,000 feet MSL (-650 m to +8,000 m)
Allowed minimum and maximum altitude for units produced or maintained after October 2021
......................................................................... -2140 feet to +65,000 feet MSL (-650 m to +20,000 m)
Functioning period: ...........................................................................................14 hours from switch-on
Power supply:...................................................................................................... service life warranty**
Maintenance: ............................................................................................................see Section 14.1***
Warranty period: ...............................................................................................................see Section 15
Service life: ..............................................................................................................see Section 14.1***
* These temperature limits do not refer to outside (ambient) temperatures but rather to temperatures inside the
processing unit. These limits are therefore not relevant until the processing unit itself has reached the temperatures
in question. In reality, these limits will rarely be reached due to the fact that CYPRES 2 must be located inside
the reserve container, and due to the insulating properties of the processing unit pouch and parachute canopy.
** If maintenance has been performed.
*** Based on currently available information
14. Technical Data
Summary of Contents for Expert CYPRES 2
Page 1: ...User Guide CYPRES 2 User s Guide english version CYPRES 2 Reliability made in Germany...
Page 64: ...CYPRES 2 User s Guide page 63 Personal Info...
Page 65: ...In case someone from the security personnel has concerns...
Page 66: ......
Page 67: ......
Page 69: ......
Page 70: ......
Page 72: ...This page intentionally left blank...