Technical description
page 15
The second-stage filter consists of active carbon fleece. Driven by the radial fan, the pre-
cleaned air flows through an
active carbon cylinder (10)
, which is retained by a
clamp-
ing ring (11)
.
Operation
Fig. 5: 4-level control system
The
aereus® arco
has a 4-level control system employing buttons. From the zero posi-
tion, the device can be switched on and set to one of 4 different output levels by increasing
or reducing the flow rate of the radial fan.
-
switch off device
-
increase output top one of the four different levels
-
display of output level
-
reduce output to one oft he four levels
-
press once: device switches of after 10mins, press twice = 20mins, etc.
The buttons simultaneously activate the high-voltage transformer, thereby increasing or
reducing the energy output for plasma generation.
Technical data
Technical data
Voltage: 230
V
Radial fan
Single-phase capacitor motor, type D2E 146-
HR93-01, 230 V AC 50 Hz, 0.33 A, 2,350 rpm
Transformer, high-voltage:
3 KV, max. 100 VA, 230 V,
load factor = 100 %
Material of functional frame:
Aluminium
Outer case:
aluminium, various designs available
plasmaNorm®
oxidation:
Electrodes of stainless steel, dielectric
hydroSorp®
filter
Ester foam material
dimensions: 560 x 250 x 15 mm
High-performance adsorber:
High Performance activ carbon