AIRFLOW: DUCTING & FAN SPEED
D. DIMENSION, SPACE REQUIREMENT AND VENTILATION
Please check dimensions of the model you intend to install and ensure that the unit has a minimum of 1 feet of
clearance from the top. If the unit is ducted to vent the exhaust air, ensure that sufficient clearance is available.
Ensure that air intake to the unit is not blocked or obstructed. It is recommended that the unit be strapped to a wall
for safety.
If the unit is installed in an enclosed room:
a. The room size must exceed 1,000 cubic feet OR
b. The room must have a louvered door or similar ventilation OR
c. The unit must be ducted to vent the exhaust air out of the enclosed area.