CAMPING
D-2
CAUTION
: BEFORE USING THE ALARM HUSH FEATURE, IDENTIFY THE SOURCE OF
THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS.
FLASHING L.E.D. LIGHT:
This smoke detector is equipped with a flashing red indicator light. The light
is located under the test button and will flash every 30-40 seconds to indicate that the smoke detector is
receiving power.
TESTING:
Test by pushing the test button on the cover and holding it down for a minimum of 2 seconds.
This will sound the alarm if all the electronic circuitry, horn and battery are working. If no alarm sounds the
unit has defective batteries or other failure. You can also test the alarm by blowing smoke into it.
TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION.
Erratic or low sound coming
from your alarm may indicate a defective detector, and it should be returned for service.
FALSE ALARMS
Smoke detectors are designed to minimize false alarms. Cigarette smoke will not normally set off the
alarm, unless the smoke is blown directly into the detector. Combustion particles from cooking may set off
the alarm if the detector is located close to the cooking area. Large quantities of combustible particles are
generated from spills or when broiling. Using the fan on a range hood which vents to the outside (non-
recirculating type) will also help remove these combustible products from the kitchen.
MODEL 0916 HAS
A "HUSH" CONTROL
that is extremely useful in a kitchen area or other areas prone to nuisance alarms.
For more information refer to
OPERATION AND TESTING.
If the detector does alarm, check for fires
first. If a fire is discovered, get out and call the fire
department. If
no fire is present, check to see if other reasons may have caused the alarm.
MAINTENANCE
BATTERY REPLACEMENT
To replace-the battery remove the detector from the mounting plate by rotating the detector in the direction
of the "OFF" arrow on the cover.
The Model 0916 Smoke Detector
uses one (1) 9-volt battery. The
SMOKE DETECTOR
is
powered by a
9V carbon zinc battery (alkaline
battery may also be used). A fresh battery should last for one year under
normal operating condition. This detector has a low battery monitor circuit that will cause the detector to
"chirp" approximately every 30-40 seconds for a minimum of seven (7) days when the battery gets low.
Replace the battery when this condition occurs.
USE ONLY THE FOLLOWING 9 VOLT BATTERIES
FOR SMOKE DETECTOR REPLACEMENT
Carbon-zinc type:
EVEREADY 216 OR 1222, GOLD PEAK 1604P OR 1604S
Alkaline type:
EVEREADY 522; DURACELL MN 1604, Gold Peak 1604A
Lithium type:
ULTRALIFE U9VL. NOTE:
REGULAR TESTING IS RECOMMENDED.
WARNING
USE ONLY THE BATTERIES SPECIFIED. USE OF DIFFERENT
BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE DETECTOR.
NOTE
:
IF AFTER BATTERY REPLACEMENT, THE UNIT CONTINUES TO CHIRP, WAIT FOR
APPROXIMATELY 7 MINUTES. THE "HUSH" FEATURE MAY HAVE BEEN ACTIVATED
ACCIDENTALLY WHILE CHANGING THE BATTERIES AND WILL RESET AUTOMATICALLY
Summary of Contents for Land Yacht 2006
Page 1: ...AIRSTREAM AN AMERICAN LEGEND LAND YACHT MOTORHOME OWNERS MANUAL 2006...
Page 2: ......
Page 11: ...WARRANTY AND SERVICE A 7 MAINTENANCE RECORDS DATE DEALER SERVICE PERFORMED...
Page 12: ...WARRANTY AND SERVICE A 8 NOTES...
Page 30: ...CHASSIS C 12 NOTES...
Page 74: ...ELECTRICAL SYSTEM H 5...
Page 75: ...ELECTRICAL SYSTEM H 6...
Page 84: ...ELECTRICAL SYSTEM H 15 110 Volt Breaker Panel 30 AMP...
Page 85: ...ELECTRICAL SYSTEM H 16 110 VOLT BREAKER PANEL 50 AMP...
Page 87: ...ELECTRICAL SYSTEM H 18 NOTES...
Page 99: ......
Page 100: ......