Maintenance
2019 International
8-17
120-Volt/30- and 50-Amp Diagrams
The following electrical diagrams are representative of the National Electric Code (NEC) and Canadian Standards
Association (CSA). All circuits are NEC with the exception of CSA circuits as specified in each respective table.
23CB International (30 Amp)
Main Circuit, 30 Amp
Circuit 1, 20 Amp
A
Air Conditioner
16.0 Amps
Circuit 2, 15 Amp
B
Converter (Wired Internally)
8.0 Amps
Circuit 3, 15 Amp
C
Microwave Receptacle
12.0 Amps
Circuit 4, 15 Amp
D
Inverter Receptacle
0.0 Amps
E
Inverter
0.0 Amps
F
Blu-Ray Player Receptacle
1.5 Amps
F
Blu-Ray Player Receptacle - CSA 1.0 Amps
G
Dinette Receptacle
1.5 Amps
G
Dinette Receptacle - CSA
1.0 Amps
H
Living Area TV Receptacle
1.5 Amps
H
Living Area TV Receptacle - CSA
1.0 Amps
J
Bedroom TV Receptacle
1.5 Amps
J
Bedroom TV Receptacle - CSA
1.0 Amps
Circuit 5, 15 Amp
K
Water Heater (Wired Direct)
12.0 Amps
Circuit 6, 15 Amp (GFCI)
L
Bathroom Receptacle
1.5 Amps
L
Bathroom Receptacle - CSA
1.0 Amps
M
Refrigerator Receptacle
2.7 Amps
N
Outside Receptacle
1.5 Amps
N
Outside Receptacle - CSA
1.0 Amps
P
Galley Receptacle
1.5 Amps
P
Galley Receptacle - CSA
1.0 Amps
R
CS Bedroom Receptacle
1.5 Amps
R
CS Bedroom Receptacle - CSA
1.0 Amps
DC to AC 1000W Inverter Rated at 8.5 Amp
Inverting
15 Amp Fuse for Overcurrent. Transfer Switch rated
at 15 Amp. UL 458 Tested. ULC
Summary of Contents for 2019 International
Page 1: ...2019 International Owner s Manual...
Page 4: ...2019 International NOTES...
Page 6: ...2019 International 1 2 Introduction NOTES...
Page 30: ...2019 International 4 6 NOTES Floor Plans And Specifications...
Page 48: ...2019 International 5 18 Interior NOTES...
Page 58: ...2019 International 6 10 Exterior NOTES...
Page 82: ...Maintenance 8 16 2019 International 22 22 Electrical Diagrams 12 Volt Main Schematic...
Page 99: ...Maintenance 2019 International 8 33 NOTES...
Page 100: ...2019 International 8 34 Maintenance NOTES...
Page 103: ......