AirStage AS A07L Operating Manual Download Page 8

En-7

TROUBLESHOOTING

The following conditions are not breakdowns or operation failures.

Symptom

Doesn’t operate immedi-
ately:

Airflow is weak or stops:

Flashing lamps:

Noise is heard:

Smells:

Fog comes out of the
indoor unit:

Steam comes out of the
indoor unit:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the compressor will not
operate for about 3 minutes, in order to prevent fuse blowouts.

Whenever the electrical breaker is turned off then on again, the protection circuit
will operate for about 3 minutes, preventing unit operation during that period.

When Heating operation is started, indoor unit's fan may temporarily stop, to al-
low internal parts to warm up.

During Heating operation, if the room temperature rises above the thermostat
setting, the outdoor unit will stop, and the indoor unit's fan will stop. If you wish to
warm the room further, set the thermostat for a higher setting.

During oil recovery operation, the air flow may stop for approximately 10 min-
utes.

During Heating operation, the unit will temporarily stop operation (between 4 and
15 minutes) as the Automatic Defrosting mode operates.

The fan may operate at low speed during Dry operation or when the unit is moni-
toring the room's temperature.

In the monitor AUTO operation, the fan will operate at low speed.

See Page

4

4

4

4

4

4

4

The OPERATION indicator lamp (green)
flashes:

The OPERATION indicator lamp (green)
flashes:

The OPERATION indicator lamp (green)
and TIMER indicator lamp (red) are flash-
ing alternately:

The OPERATION indicator lamp (green)
and TIMER indicator lamp (red) are flash-
ing simultaneously:

The OPERATION indicator lamp (green)
lights up and the TIMER indicator lamp
(red) flashes:

An oil recovery operation is being per-
formed.

An automatic defrosting operation is be-
ing performed.

It has recovered from a power outage.

It is operating in trial operation mode.
Ask a manager as there may be mainte-
nance being conducted.

This is the standby state.

In the following conditions there are sounds of water flowing from the indoor unit
and the operation sound becomes loud. These are the sounds of the flowing of
refrigerant.

When operation starts
When oil recovery operation finishes
When automatic defrosting operation finishes

During operation, a slight squeaking sound may be heard. This is the result of
minute expansion and contraction of the panel due to temperature changes.

During Heating operation, a sizzling sound may be heard occasionally. This sound
is produced by the Automatic Defrosting operation.

Some smell may be emitted from the indoor unit. This smell is the result of room
smells (furniture, tobacco, etc.) which have been taken into the air conditioner.

During Cooling operation, a thin mist may be seen emitted from the indoor unit.
This results from the sudden Cooling of room air by the air emitted from the air
conditioner, resulting in condensation and misting.

During Heating operation, the outdoor unit’s fan may stop, and steam may be
seen rising from the unit. This is due to the Automatic Defrosting operation.

During Heating operation, water may be produced from the outdoor unit due to
the Automatic Defrosting operation.

Summary of Contents for AS A07L

Page 1: ...MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI MANUAL DE INSTRU ES AS E07L AS E09L AS E12L AS E14L AS A07L AS A09L AS A12L AS A14L Compact Wall Mounted Type En...

Page 2: ...als or plants in the direct path of the air flow Do not direct air flow at fireplaces or heating apparatus Do not block or cover the inlet port and outlet port Do not climb on or place objects on the...

Page 3: ...5 TIMER Indicator Lamp Orenge It lights on while timer is working 6 Remote Control Signal Receiver This is the place to receive the signals from the remote controller 7 FILTER Indicator Lamp Red It l...

Page 4: ...button on the operating control panel Operation mode AUTO Fan speed AUTO Setting temperature 23 C When Auto mode cannot be selected it will operate in the same mode as the other indoor unit in the sa...

Page 5: ...heated Microcomputer controlled automatic defrosting When using the Heating mode under conditions of low outdoor air temperature high humidity frost may form on the outdoor unit resulting in reduced...

Page 6: ...king sure the 2 lower tabs are returned properly to their holes in the panel 2 The fixing axle of the intake grille is installed on the front panel 3 Lay down the intake grille 2 2 2 2 2 CLEANING AND...

Page 7: ...orizing filter frame with the 6 hooks at the rear of the air filters 4 Install the 2 air filters and close the intake grille Cleaning body Wash the body with warm water and then dry with a clean and s...

Page 8: ...d TIMER indicator lamp red are flash ing alternately The OPERATION indicator lamp green and TIMER indicator lamp red are flash ing simultaneously The OPERATION indicator lamp green lights up and the T...

Page 9: ...nding on the room conditions While high humidity or the room temperature is high See Page 4 4 4 5 4 SPECIFICATIONS Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for...

Reviews: