En-8
SPECIFICATIONS
●
Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor
unit.
According to IEC 704-1 and ISO 3744.
AB A12L
AB A14L
AB A18L
AB A24L
230 V~50 Hz
198 to 264 V
3.60
4.05
5.30
6.60
4.10
5.00
5.60
7.70
199
990
655
28
MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
[kW]
HEATING CAPACITY
[kW]
DIMENSIONS & WEIGHT
HEIGHT
[mm]
WIDTH
[mm]
DEPTH
[mm]
WEIGHT
[kg]
AB A30L
AB A36L
AB A45L
AB A54L
230 V~50 Hz
198 to 264 V
8.80
10.5
12.7
14.1
9.10
12.7
13.7
15.8
240
1,660
700
48
MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
[kW]
HEATING CAPACITY
[kW]
DIMENSIONS & WEIGHT
HEIGHT
[mm]
WIDTH
[mm]
DEPTH
[mm]
WEIGHT
[kg]
The following conditions may not be breakdowns so check again.
Symptom
Doesn’t operate at all:
The operation mode
cannot be changed:
Poor Cooling
(or Heating)
performance:
See page
—
—
—
4
4
4
—
5
—
—
—
—
—
Items to check
●
Has there been a power failure?
●
Has a fuse blown out, or a circuit breaker been tripped?
●
Is the main power switch set to the OFF position?
●
Are you trying to engage in an operation different from the priority state?
●
Is it in standby state?
●
Are you trying to change to an operation different from the priority conditions?
●
Did you adjust the room temperature settings (thermostat) correctly?
●
Is the air filter dirty?
●
Are the air conditioner’s inlet port or outlet port blocked?
●
Is there a window or door open?
●
In the case of Cooling operation, is a window allowing bright sunlight to enter?
(Close the curtains.)
●
In the case of Cooling operation, are there heating apparatus and computers
inside the room, or are there too many people in the room?
●
Is the fan speed set to low?
In the following situations stop operation immediately and get in touch with authorized
service personnel.
●
The problem cannot be solved even when the troubleshooting checks have been performed.
●
The OPERATION indicator lamp (red) is flashing very fast.
●
The wired remote controller or simple remote controller indicate EE (when connected).
●
It has burning smell.
9369308024_OM_en.p65
31/8/06, 10:12
8
Summary of Contents for AB A12L
Page 42: ...Gr 1 1 2 3 3 4 5 7 XAPAKTHPITIKA TIKA 8 7 9369308024_OM_el p65 1 9 06 13 34 1...
Page 47: ...Gr 6 9 9 9 9 Q 9 9 12 AB A30 36 45 54L 1 9 2 9 9 3 9 9 9 9369308024_OM_el p65 1 9 06 13 34 6...
Page 55: ...Sc 6 9369308024_OM_Sc p65 NO _ PMLPSLQRLRQi NK OK 0123 PK...
Page 58: ...Ru 1 1 2 3 3 4 5 7 8 9369308024_OM_ru p65 1 9 06 13 35 1...
Page 63: ...Ru 6 12 AB A30 36 45 54L 1 2 3 9369308024_OM_ru p65 1 9 06 13 35 6...
Page 74: ...9369308024_OM_pt p65 6 9 06 11 24 9...