AirSep ImPulse Elite Patient Manual Download Page 1

ImPulse

 Elite Patient Manual

ImPulse

 Elite OCD System

Patient Manual

401 Creekside Drive  •  Buffalo, New York 14228-2085  USA

Summary of Contents for ImPulse Elite

Page 1: ...ImPulse Elite Patient Manual ImPulse Elite OCD System Patient Manual 401 Creekside Drive Buffalo New York 14228 2085 USA ...

Page 2: ...ImPulse Elite Patient Manual ...

Page 3: ...nder Connection 7 Testing and Replacing Battery 9 Turning On the Unit for Proper Oxygen Usage 10 Turning Off the Unit 12 Alarm Light Indicators 12 Switching to Continuous Flow 13 Removing Replacing the Cylinder 13 ImPulse Elite as a Portable Unit 14 Proper Care and Maintenance 15 Troubleshooting Guide 16 Equipment Provider Information Specifications 17 Limited Warranty 18 Table of Contents i ...

Page 4: ...ImPulse Elite Patient Manual ...

Page 5: ...lowing as shown in Figure 1 below The Ambulatory Oxygen System for Complete Patient Mobility Not shown 1 OneAlkaline D Energizer Battery ImPulse Elite OCD System Patient Manual Note The carrying case is available separately Figure 1 ImPulse Elite Oxygen Conserving Device Components 1 ...

Page 6: ...ffer up to 6 lpm efficiency Fail safe electronic circuitry and alarm system provide added assurance of proper unit function and oxygen delivery Audible alarm when device does not detect inhalation inspiration if cannula is disconnected or tubing kinked or if the unit is inadvertently left on when not in use Only minimal maintenance required Designed for maximum patient mobility Economical way for ...

Page 7: ...th nasal dehydration that can result from constant flow into the nostrils Maximizing Delivery with ImPulse Elite ImPulse Elite s advanced electronics enable it to respond effectively to a patient s respiratory cycle ImPulse Elite senses the start of inhalation Because only a small amount of oxygen is actually required to oxygenate the blood effectively ImPulse Elite delivers the precise amount whe...

Page 8: ...sed physician This device must be used only under the supervision of a licensed physician High purity oxygen promotes rapid burning Do not allow smoking or open flames within five feet of this device the portable oxygen cylinder or any oxygen carrying accessory If you observe that the oxygen conserving device is not working properly or you feel ill contact your Equipment Provider and or physician ...

Page 9: ...onsumption of oxygen in the cylinder Do not use this device with a humidifier or expose it to water or other liquids Do not expose the device to extreme temperatures Do not use this device with the batteries removed if the oxygen tubing is kinked or obstructed if the device was tampered with or opened by anyone other than your Equipment Provider 5 ...

Page 10: ...ng any change to the flow selector setting Description of Parts SecuringKnob Oxygen Outlet Cylinder ContentsGauge Pulse Flow Continuous Flow Switch BatteryTest Button Low Battery Yellow Indicator Pulse Flow Green Indicator Alarm Red Indicator Battery Compartment not shown Flow Selector On Off Switch Figure 2 6 Brass CGA Sealing Washer Figure 2a Figure 2b Easily connects to anystandardpost valve cy...

Page 11: ...oxygen source Use this device and the oxygen cylinder only with clean dry oil free hands Oxygen in the cylinder is under high pressure Do not open the cylinder valve without the ImPulse Elite unit properly connected to the cylinder Your Equipment Provider will review proper cylinder care and connection procedures with you the first time you operate your unit Refer to the procedure on the following...

Page 12: ...gure 6 Figure 6 Figure 3 1 Loosen the ImPulse Elite securing knob To ensure a leak tight seal between the cylinder valve and the unit make sure the sealing washer is present in the center of the unit before installation Figure 3 2 Align the two parallel alignment pins Figure 4 on the unit with the holes on the neck of the cylinder Figure 5 SealingWasher Figure 4 Alignment Pins Figure 5 Alignment H...

Page 13: ...remove the ImPulse Elite from the cylinder although you may find it easier to replace the battery within the battery compartment door if the unit is first removed from the cylinder 2 If the unit is not connected to the cylinder simply hold the unit with one hand while you press in and lift up on the battery compartment latch with your other hand Figure 7 If the unit is connected to the cylinder st...

Page 14: ...y regardless of whether or not a cannula is connected to the oxygen outlet The green PULSE FLOW indicator illuminates to indicate a good battery If the battery requires replacement the green PULSE FLOW and yellow LOW BATTERY indicators illuminate Turning On the Unit for Proper Oxygen Usage Note Do not use a mask with the ImPulse Elite unit Amask may not conform to the face properly enough for the ...

Page 15: ...atically calibrates and reaches sensitivity within approximately 15 seconds Then the green light shuts off and the unit emits a short burst of oxygen This indicates ImPulse Elite is ready for use 5 Connect your cannula to the oxygen outlet You may use up to a 25 ft 7 5 m cannula if desired Figure 11 6 Turn the cylinder valve slowly one full turn counter clockwise to begin oxygen flow 7 Make sure t...

Page 16: ... not on battery life is preserved ON Flow Selection Green No Pulse flow Yellow Green Yes Intermittent Battery almost discharged Prepare to replace battery within 20 30 minutes Red Yes Continuous No inspiration detected for approximately 30 seconds cannula may be disconnected tubing kinked or unit remains on when not in use BAT TEST Green No Sufficient battery life Yellow Green No Battery almost di...

Page 17: ...F position to preserve battery life as this is a manual override and no audible or visual alarm indicators are available in this temporary setting Caution The continuous flow setting uses substantially more oxygen than the normally used pulse flow setting Make sure the cylinder contents gauge is observed often when operating the unit as a continuous flow device 13 Figure 13 Removing Replacing the ...

Page 18: ...peratures The universal style carrying case as shown in Figure 14 can be used with the unit During use ImPulse Elite should remain in your carrying case This ensures added protection for the unit and allows discreet use Simply check periodi cally to ensure that your cannula connec tion is secure and that the cylinder shutoff valve remains in the open position one full turn counterclockwise to enab...

Page 19: ...o the plastic manufacturer alcohol and alcohol based products isopropyl alcohol concentrated chlorine based products Ethylene Chloride and oil based products Pine Sol Lestoil These are NOT to be used to clean the plastic housing on the ImPulse Elite OCD These chemicals and the cleaners that contain them will crystallize the plastic and break down the plastic s molecular properties Replace the disp...

Page 20: ...shooting Guide Power switch ON but no lights display Intermittent power intermittent pulsing lights flash alarm sounds Oxygen leaks from unit Constant flow of oxygen from unit Unit does not deliver oxygen Any other unit problem Replace battery Insert battery properly by referencing polarity guide on inside of battery compartment door Replace Alkaline battery with new D cell Energizer battery Ensur...

Page 21: ...ors Alarm No inspiration Audible Visual red Low Battery Audible Visual yellow Pulse Flow Visual green indicates good battery Continuous 2 lpm oxygen manual switch Flow Contents Red Refill Zone 0 500 psi Gauge Green Shaded Zone 500 2 200 psi Green Outlined Zone 2 200 3 000 psi Operating 32 F to 104 F 0 C to 40 C Temperature Maximum Cylinder Pressure 3 000 psi Equipment Provider Information 17 ...

Page 22: ...ight charges Replacement parts shall be warranted as stated above for the unexpired portion of the original five year parts warranty as specified on the original invoice provided This warranty does not extend to any item or part subjected to misuse accident improper maintenance or application or which has been repaired or altered outside of the AirSep Corporation factory without the express prior ...

Page 23: ...ImPulse Elite Patient Manual MN092 1 Rev 04 04 B ...

Page 24: ...ImPulse Elite Patient Manual For service on your ImPulse Elite oxygen conserving device contact Manufactured by AirSep Corporation 401 Creekside Drive Buffalo NY 14228 2085 USA ...