background image

SAFETY NOTICE

GENERAL ADVICE BEFORE USE

·Ensure the safety of the location in which cooler is to be used.
·Ensure the floor or ground is smooth and sound.
·Ensure you allow at least 20inch air space all around the cooler.
·When in position LOCK the casters to prevent rolling.
·Never use the cooler at more than 2° incline.

  FOR MAXIMUM EFFICIENCY

·In airtight areas use vertical exhaust into ceiling.
·If possible locate exhaust outlet through a window or door to outside.
·Ensure correct electricity supply.

CAUTION

Do not place cooler on uneven, unstable or inclined surface.
(This could cause malfunction)

When storing the cooler, ensure that it is kept in a dry, cool place.
(To prevent corrosion and malfunction)

If not being used for some time or if lightening is present, always unplug 
from power. (To prevent risk of electric shock, short circuit or fire)

Do not spray water on to the cooler nor use solvents such as benzene, 
thinner or alcohol for cleaning.
(There is a risk of electric shock and / or short circuit)

Designed for indoor usage.

4

Summary of Contents for HSC-14S

Page 1: ...follow them at all times The Air Conditioners are specified for use on a 115V 60Hz 1ph power supply You must check that the local electricity supply is the same and have the appropriate plug fitted by...

Page 2: ...RIPTION Front View Back View Control Panel OPERATING INSTRUCTIONS On Off Operation Selection of Area Room or Spot Cooling Economic Mode Temperature Control Off Timer Indicator and Operational Error Al...

Page 3: ...ury Do not use an extension cord Risk of fire and or electric shock Ensure mains plug is clean and securely plugged in Otherwise it may short causing smoke and fire Do not kink or sharply bend the pow...

Page 4: ...xhaust outlet through a window or door to outside Ensure correct electricity supply CAUTION Do not place cooler on uneven unstable or inclined surface This could cause malfunction When storing the coo...

Page 5: ...LOCKABLE Electric Panel ACCESS BY AUTHORISED SERVICE personnel only Power PLUG Condenser Outlet HOT AIR Evaporator Filter AMBIENT AIR INTAKE Condenser Filter Water level INDICATOR To check water level...

Page 6: ...long distance you can control the machine by wired remote control Room If the LED is On the displayed temperature is for Room temp If the LED is Off the displayed temperature is for spot temp Comp Whe...

Page 7: ...art up automatically To STOP the unit press the POWER button once again 2 To change fan speed press the Low button 3 If you wish to operate on fan only press the COOL button To resume cooling press th...

Page 8: ...ture push cool and button simultaneously for three seconds 2 If you want to change temperature unit push and button simultaneously for three seconds If the compressor operation is stop in Room Temp Mo...

Page 9: ...ou push either or button the setting temperature is changed 3 The display showing the set temperature will blink 3 times 4 Display range Setting range Cooling operates when Room Spot temperature is mo...

Page 10: ...ress the button you will increase the time to off period by 30mins up to 10 hours and 1 hour thereafter up to 24 hours The display will show 5 for 30min and 1 for an hour e g One and a half hours will...

Page 11: ...r tank is not positioned correctly the LED Align Drain Tank light will be on 3 HIGH PRESSURE E1 is displayed and the Error LED will be on when the pressure of the compressor is too high and the high p...

Page 12: ...ir 3 Clean evaporator and condenser units with a vacuum cleaner or compressed air MAINTENANCE 1 After cleaning completely dry the inside of the unit by operating on Fan Mode only for 3 to 4 hours 2 Tu...

Page 13: ...blown Exchange fuse in board Breaker on switch board Check load capacity and reset tripped Ambient temp too high Use only below 105 over105 Filter blocked with dust Clean Filter Dust in heat exchanger...

Page 14: ...upply 115Va c 60Hz 1Ph inch 19 3 X 23 6 X 46 8 Weight lb 180 Evaporator Air Flow ft3 m 440 Power Consumption kW 1 59 Current Consumption Amp 13 3 Nema Plug 5 15 Refrigerant lb R410A 1 33 Air Filter Al...

Page 15: ...contact your dealer or distributor If the problem is as a result of a production fault or failure repairs will be undertaken free of charge during the period of warranty subject to the following warra...

Page 16: ...2 502 5519 E mail airrex hdtek com Website www airrex co kr Designs and specifications of products are subject to change without prior notice for the improvement of products USA DISTRIBUTOR AIRREX USA...