Airquality TH-920DTX Instruction Manual Download Page 4

1. Press

to enter program setting.

(Temperature reading shall be flashing on LCD)

2. Press

to set desired

for 1st program-period(event).

3. Press

after temperature-setpoint for

program-period completed.

(you shall read "Hour & Start Time" begin flashing)

4. Press

to set desired

for

1st program-period (event).

6.Repeat programming procedure

to complete each of temperature & time setpoints
for every program-period(event) of weekdays(5-d).

And to complete programming Saturday & Sunday

after programming weekdays was completed.

7. Pressing

and then

pressing

to run programs.

temperature-setpoint

1st

time-setpoint

twice

5. Press

to enter setting temperature setpoint for

program-period (event),after Time setpoint

of 1st program-period completed.
(flashing temperature reading appears on LCD again)

2nd

All 5 weekdays shall have same programming,
Saturday

Sunday to be programmed separately.

Programming 5-1-1d

or

or

or

Factory preset programs period
(initial default)

Mode 5-1-1d P4 Factory Preset

Temperature

Mon. ~ Fri.

Time

Heating mode

Cooling mode

MORN(P1)

6:00

70

(21

)

75

(24

)

DAY(P2)

8:30

60

(15.5

)

85

(29.5

)

EVEN(P3)

4:30

PM

70

( 21

)

75

(24

)

NIGHT(P4) 10:30

PM

65

(18.5

)

80

(26.5

)

Temperature

Saturday

Time

Heating mode

Cooling mode

MORN(P1)

7:00

70

(21

)

75

(24

)

DAY(P2)

8:30

70

(21

)

85

(29.5

)

EVEN(P3)

4:30

PM

70

(21

)

75

(24

)

NIGHT(P4) 10:30

PM

65

(18.5

)

80

(26.5

)

Temperature

Sunday

Time

Heating mode

Cooling mode

MORN(P1)

7:00

70

(21

)

75

(24

)

DAY(P2)

8:30

60

(15.5

)

85

(29.5

)

EVEN(P3)

4:30

PM

70

( 21

)

75

(24

)

NIGHT(P4) 10:30

PM

65

(18.5

)

80

(26.5

)

°F

°C

°F

°F

°C

°C

°F

°C

°F

°C

°C

Temperature

Mon ~ Fri

Time

Heating mode

Cooling mode

MORN(

P1

)

6:00

70

(21

)

75

(24

)

DAY(P2)

8:30

60

( 15.5

) 85

(29.5

)

NOON(P3)

12:00pm

70

(21

) 75

(24

)

BREAK(P4)

2:00pm

60

(15.5

) 85

(29.5

)

EVEN(P5)

4:30pm

70

( 21

)

75

(24

)

NIGHT(P6)

10:30pm

65

(18.5

) 80

(26.5

)

Temperature

Saturday

Time

Heating mode

Cooling mode

MORN(P1)

7:00

70

(21

)

75

(24

)

DAY(P2)

8:30

70

(21

)

75

(24

)

NOON(P3)

12:00pm

70

(21

) 75

(24

)

BREAK(P4)

2:00pm

70

(21

) 75

(24

)

EVEN(P5)

4:30pm

70

(21

)

75

(24

)

NIGHT(P6)

10:30pm

65

(18.5

) 80

(26.5

)

Temperature

Sunday

Time

Heating mode

Cooling mode

MORN(P1)

7:00

70

(21

)

75

(24

)

DAY(P2)

8:30

70

(21

)

75

(24

)

NOON(P3)

12:00pm

70

(21

) 75

(24

)

BREAK(P4)

2:00pm

70

(21

) 75

(24

)

EVEN(P5)

4:30pm

70

(21

)

75

(24

)

NIGHT(P6)

10:30pm

65

(

18.5

)

80

(26.5

)

Mode 7-d

P6 factory preset

and

will not appear in P6 mode.

NOON

BREAK

°C

°F

°C

°C

°C

°F

°F

°F

°F

°F

°C

°C

Within programming mode, transmitter thermostat shall automatically resume its functioning 30 seconds
after there was no any further data input.

PROGRAMMING INSTRUCTIONS-

-Transmitter Thermostat

2

SAVE THESE INSTRUCTIONS

Summary of Contents for TH-920DTX

Page 1: ...t into R F Receiver as part of commissioning procedure to ensure that your R F Receiver will only respond to instruction sent to it from Transmitter The special feature of blue backlit soft Key which...

Page 2: ...in Transmitter Flip to open the flap on front plastic housing Upper compartment 2 x 1 5V AAA for powering transmitter Lower compartment 2 x 1 5V AAA for backlit Internal setting adjustable to users Th...

Page 3: ...y to complete programming 1 Press to enter program setting you shall read temperature reading in flashing 2 Press or to set desired for program period event 3 Press to enter setting for 1st program pe...

Page 4: ...26 5 Temperature Saturday Time Heating mode Cooling mode MORN P1 7 00 70 21 75 24 DAY P2 8 30 70 21 85 29 5 EVEN P3 4 30 PM 70 21 75 24 NIGHT P4 10 30 PM 65 18 5 80 26 5 Temperature Sunday Time Heatin...

Page 5: ...indicate its executing 5 Upon is in executing Press shall immediate this Overrride Permanent Hold Temperature Permanent Hold Temperature D Temperature Until Vacation Hold Hold temperature at desired s...

Page 6: ...RMOSTAT RECEIVER RECEIVER D D 230Vac Fused 16 AMP N L TRANSMITTER THERMOSTAT BOILER RECEIVER T1 T2 D N L COOLER N L SM ACUATOR O W Y BL 230Vac Fused 16 AMP TRANSMITTER THERMOSTAT BOILER RECEIVER D N L...

Page 7: ...READ ALL WIRE SIZING VOLTAGE REQUIREMENT AND SAFETY DATA AVOID PROPERTY DAMAGE AND PERSONAL INJURY SAVE THESE INSTRUCTIONS PROPOSED WIRING APPLICATION RV 0356H 230Vac Fused 16 Amp RX Heating Elements...

Reviews: