4/8/2008R series service manual 

PAGE 4 OF 20 

Liquid side/ Gas side     

mm 

Ф

6.35/

Ф

9.53

 

Ф

6.35/

φ

12.7

 

 

3.2 Outdoor unit 

Outdoor Model 

MSM-18HRN1 

MSM-21HRN1 

Power supply 

Ph-V-Hz 

1Ph,220-240V~,50Hz 

1Ph,220-240V~,50Hz 

Capacity                                         

Btu/h 

18000   

21000   

Capacity                                         

5275   

6155   

Input                       

1680   

2000   

Rated current       

8.0   

9.7   

Cooling 

EER                 

w/w 

3.1   

3.04 

Capacity                                         

Btu/h 

20000 

24000 

Capacity                                         

5862   

7034   

Input                       

1680   

2050 

Rated current       

8.0   

9.8   

Heating 

EER                 

w/w 

3.45   

3.42   

Max. input power   

2280 

2520 

Max. current                               

9.8 

12.0 

Starting current                               

21.7 

21.7 

Model   

 

PA108X1C-4FTDE ; 

PA108X1C-4FTDE 

PA108X1C-4FTDE ;   

PA145X2C-4FT   

Type   

 

ROTARY     

ROTARY     

Brand   

 

TOSHIBA 

TOSHIBA 

Capacity           

Btu/h 

8769 X 2 

8769+12014 

Input                     

885X2 

885+1200 

Rated current(RLA)   

4.15X2 

4.15+5.6 

Locked rotor Amp(LRA)       

40X2 

40+57 

Thermal protector           

 

Internal 

Internal 

Capacitor             

uF 

25uF/370VAC X 2 

25+35uF/370VAC 

Compressor 

Refrigerant oil       

ml 

350X2 

350+480 

Model   

 

YDK60-6 

YDK60-6 

Brand   

 

Welling 

Welling 

Input                       

111 

111 

Capacitor               

uF 

4uFx2 

4uFx2 

Outdoor fan 
motor 

Speed                 

r/min 

830/650 

830/650 

a.Number of rows 

 

b.Tube pitch(a)x row pitch(b)   

mm 

25.4x24 

25.4x24 

c.Fin spacing                               

mm 

1.7 

1.7 

d.Fin type (code) 

 

  Hydrophilic aluminium 

  Hydrophilic aluminium 

e.Tube outside dia.and type   

mm 

Ф9.53, Innergroove tube 

Ф9.53, Innergroove tube 

f.Coil length x height x width   

mm 

810X610X44 

810X610X44 

Outdoor coil 

g.Number of circuits 

 

2/2 

2/2 

Outdoor air flow                         

m3/h 

2200 

2200 

Outdoor noise level                 

dB(A) 

56 

56 

Dimension(W*H*D) 

mm 

895X655X345 

895X655X345 

Packing    (W*H*D) 

mm 

1050X780X470 

1050X780X470 

Outdoor 
unit 

Net/Gross weight     

Kg 

76/82 

76/82 

Refrigerant type                                 

R410A g 

980X2 

900+1100 

Design pressure(Hi/Lo)                           

MPa 

4.4/2.0 

4.4/2.0 

Liquid side/ Gas side     

mm(inch) 

Ф6.35/Ф9.53 

Ф6.35/Ф9.53; Ф6.35/Ф12.7 

Max. refrigerant pipe length     

15 

15 

Refrigerant 
piping 

Max. difference in level             

10 

10 

Connection wiring               

 

No 

   

Plug type 

 

No 

   

Summary of Contents for MSM-09HRN1

Page 1: ...SERVICE MANUAL AirQ AIRCONDITIONER MULTI SPLIT TYPE MSM 09HRN1 MSM 12HRN1 MSM 30HRN1 V1 0 Dec 2007...

Page 2: ...manual PAGE 1 OF 20 Multi SERIES 1 Features 2 2 Function 2 3 Specification 3 4 Dimensions 6 5 Refrigeration cycle diagram 8 6 Wiring diagram 9 7 Troubleshooting 12 8 Electronic function 14 9 Characte...

Page 3: ...re sensor Pipe temperature sensor Sensing by room temperature Maintain the room temperature in accordance with the setting temperature Room temperature control Indoor fan is delayed for 5 sec at the s...

Page 4: ...ydrophilic aluminium Hydrophilic aluminium e Tube outside dia and type mm 7 innergroove tube 7 innergroove tube f Coil length x height x width mm 538X252X26 74 538X252X26 74 Indoor coil g Number of ci...

Page 5: ...F 25uF 370VAC X 2 25 35uF 370VAC Compressor Refrigerant oil ml 350X2 350 480 Model YDK60 6 YDK60 6 Brand Welling Welling Input W 111 111 Capacitor uF 4uFx2 4uFx2 Outdoor fan motor Speed r min 830 650...

Page 6: ...al Internal Capacitor uF 45 35uF 370VAC 45 35uF 370VAC Compressor Refrigerant oil ml 750 480 750 480 Model YDK50 4G1 YDK50 4G1 Brand Welling Welling Input W 200 200 Capacitor uF 4uFx2 4uFx2 Outdoor fa...

Page 7: ...s service manual PAGE 6 OF 20 Thermostat type Electronic control Operation temp 17 30 Ambient temp 18 43 cooling 7 24 heating 4 Dimension 4 1 Indoor unit dimension Dimension Mode W H D 9K 790 275 190...

Page 8: ...4 8 2008R series service manual PAGE 7 OF 20 4 2 Outdoor unit dimension a Outdoor unit 18K 21K b Outdoor unit 27K 30K...

Page 9: ...ur way valve PMV1 PMV2 Electronic expansive valve T1 T2 Indoor pipe temperature sensor Condenser Four way valve Evaporator Compressor 1 drive 1 system Notice For 1 drives 2 system there are two indivi...

Page 10: ...4 8 2008R series service manual PAGE 9 OF 20 6 Wiring diagram 6 1 Indoor unit...

Page 11: ...4 8 2008R series service manual PAGE 10 OF 20 6 2 Outdoor unit For 1 drive 2 outdoor unit...

Page 12: ...4 8 2008R series service manual PAGE 11 OF 20 For 1 drive 3 outdoor unit...

Page 13: ...1 1 drive 2 Failure phenomenon LED1 LED2 LED3 Stand by High temp protect of condenser Temp sensor in condenser 1 is open circuit or short circuit Temp sensor in condenser 2 is open circuit or short ci...

Page 14: ...g applied to the fan motor rang 90v 160v between mid pin and N on CN1 NO YES Indoor PCB is defective Replace the indoor PCB YES Replace the indoor fan motor NO Is the indoor fan motor connector and co...

Page 15: ...outdoor temperature sensor connector and connection good Repair the connector and reconnect Replace the sensor and check if E5 display again NO YES Replace outdoor e box YES Is the temp more than 65...

Page 16: ...indicator illuminates Auto indicator This indicator flashes when the air conditioner is in AUTO operation ECON indicator This indicator illuminates while the air conditioner is in economic operation 8...

Page 17: ...eed is out of control When Indoor Fan Speed is too high higher than High Fan 300RPM or too low lower than 400RPM the entire unit stops and LED displays failure information and can t returns to normal...

Page 18: ...s the same as that of cooling mode 8 8 Heating mode 8 8 1 Generally the 4 way valve is open in heating mode but it is closed in defrosting mode 4 way valve must delay 2 minutes compared with compresso...

Page 19: ...ature protection under heating mode Condition Compressor Outdoor fan TE TE8 On On TE8 TE TE7 On Off Indoor exchanger temp up TE TE7 Off Off TE TE9 Off Off Indoor exchanger temp down TE TE9 On On TE In...

Page 20: ...r reselect when the set temp varies 8 11 Forced cooling function 8 11 1 Select forced cooling function with the forced cooling button or the switch 8 11 2 The compressor is unconditionally turned on a...

Page 21: ...stant and the air circulation is kept at low speed Cold air proof function takes precedence over all 8 14 4 Auto The economic running function operates in accordance with the selected running mode by...

Page 22: ...2 39 8239 25 10 52 3 1918 1 37 1988 26 9 5507 53 3 0707 0 35 2024 27 9 1245 54 2 959 1 33 3269 28 8 7198 55 2 8442 2 31 5635 29 8 3357 56 2 7382 3 29 9058 30 7 9708 57 2 6368 4 28 3459 31 7 6241 58 2...