that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated 

weighing scales shall be available and in good working order. Hoses shall be 

complete with leak-free disconnect couplings and in good condition. Before using the recovery unit, check that 

it is in satisfactory working order, has been properly maintained and that any associated electrical components 

are sealed to prevent ignition in the event of a refrigerant release. 

Consult manufacturer if in doubt. 

The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the 

relevant  Waste  Transfer  Note  arranged.  Do  not  mix  refrigerants  in  recovery  units  and  especially  not  in 

cylinders. 

If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable 

level to make certain that flammable refrigerant does not remain within the lubricant. 

The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric 

heating to the compressor body shall be employed to accelerate this process. 

When oil is drained from a system, it shall be carried out safely. 

 

Fuse parameters of the unit 

Type: 5TE or 932 or 5H      Voltage: 250V      Current: 3.15 A 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IX. Troubleshooting 

Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to failure of the   
warranty card, and may cause damage to users or their properties. 

 

 

Problems 

Reasons 

Solutions 

The air conditioning 
does not work. 

There is no electricity.   

Turn  it  on  after  connecting  it  to  a  socket  with 
electricity.   

Summary of Contents for RMAP-7001

Page 1: ...1 DRAAGBARE AIRCONDITIONER RMAP 7001 Lees deze gebruikshandleiding voorafgaand aan het gebruik van dit product en bewaar het ter referentie...

Page 2: ...t voor bedrijf gespecificeede ruimte 9 Elke persoon die betrokken is bij werken aan of openen van een koelmiddelcircuit moet een actueel en geldig certificaat hebben van een door de branche geaccredit...

Page 3: ...len Installeer en gebruik het apparaat niet in de badkamer of andere vochtige omgevingen Trek de stekker niet uit het stopcontact om het apparaat uit te schakelen Plaats geen bekers of andere objecten...

Page 4: ...irculatie 3 De meegeleverde afdichtplaat zorgt voor makkelijke raam montage en het onderhouden van een soepele stroming van de luchtafvoerpijp 4 Modern LED verlicht bedieningspaneel met gebruiksvriend...

Page 5: ...5 II Functies en componenten Component Controleer dat alle accessoires in de doos zitten en lees de instructiehandleiding voorafgaand aan het monteren van de eenheid...

Page 6: ...eze functie is niet beschikbaar in de modus SLAAP en de modus ONTVOCHTIGEN 3 OMHOOG toets Onder de timermodus drukt u op deze toets om de timer omhoog later in te stellen Onder de koelmodus drukt u op...

Page 7: ...e duur van de inschakel of uitschakeltimer SLAAPMODUS Druk voor het inschakelen van de slaapmodus De eenheid werkt met energiebesparingslogica en de laagste ventilatorsnelheid IV Veiligheidsfuncties 1...

Page 8: ...einde van de uitlaatverbinding in de ontluchtingssleuf van het achterpaneel duw naar links en voltooi de montage als getoond in afbeelding 1 1 2 Installatie van de afdichtplaat voor ramen 1 Open het r...

Page 9: ...Afb 6 Let op Het platte uiteinde van de verbindingen van de uitlaatpijp moeten op de plaats worden geklikt De slang mag niet vervormd zijn en ook geen aanzienlijke draaiing hebben meer dan 45 Houd de...

Page 10: ...waterplug eruit en het water stroomt automatisch in het waterreservoir Let op Houd de afvoerklep en de waterplug in goede staat Tijdens het aftappen kan de behuizing enigszins naar achteren worden gek...

Page 11: ...ter met neutraal reinigingsmiddel ongeveer 40 104 en droog het in de schaduw na schoon spoelen VIII Opslag van het product 1 Schroef de afvoerklep los haal de waterplug eruit en tap het water in de wa...

Page 12: ...luchtinlaat of uitlaat is geblokkeerd Verwijder obstructies Veel lawaai De airconditioning is niet op een vlak oppervlak geplaatst Plaats het apparaat op een vlakke en harde ondergrond om geluid te re...

Page 13: ...n elektronische apparatuur apart van het huishoudelijke afval moet worden weggegooid aan het einde van de levensduur Er zijn aparte inzamelsystemen voor recycling in de EU Neem voor meer informatie co...

Page 14: ...ects safety means shall only be carried by competent persons Notes The air conditioning is only suitable for indoor use and is not suitable for other applications Follow local grid interconnection rul...

Page 15: ...and maintenance shall not be made by children without supervision If the mains power cable is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order...

Page 16: ...16 II Features and Components Component Check that all accessories are in the box and please read the instruction manual before assembling the unit...

Page 17: ...his key to adjust the time upwards Under cooling mode press this key to adjust the temperature higher This function is not available under FAN mode and DEHUMIDIFYING mode 4 DOWN Key Under timer mode p...

Page 18: ...on 1 Frost Protection Function In cooling mode if the temperature of the exhaust pipe is too low the unit will automatically enter protection status if the temperature of the exhaust pipe rises to a c...

Page 19: ...ccessories 1 Half open the window and mount the window sealing plate assembly to the window as shown in Fig 2 and Fig 3 Components can be placed in horizontal and vertical direction 2 Pull various com...

Page 20: ...cannot be distorted nor has substantial turning greater than 45 Keep the ventilation of the exhaust pipe unblocked Figure 5 Figure 6 Important Notice The length of the exhaust hose shall be 280 1 500...

Page 21: ...ge the body can be tilted slightly backwards 3 If the water container cannot hold all the water before the water container is full insert the water outlet with the water plug as soon as possible to pr...

Page 22: ...ater in the water pan into other water containers or directly tilt the body to discharge the water into other containers 2 Turn on the unit adjust it to low wind ventilation mode and maintain this sta...

Page 23: ...ains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion All possible ignition sources including cigarette smoki...

Page 24: ...g form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation 2 Particular attention shall be paid to the following to ensure that by working on ele...

Page 25: ...the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The...

Page 26: ...rt the recovery unit and operate in accordance with manufacturer s instructions h Do not overfill cylinders No more than 80 volume liquid charge i Do not exceed the maximum working pressure of the cyl...

Page 27: ...ry units and especially not in cylinders If compressors or compressor oils are to be removed ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does...

Page 28: ...he air conditioning on a flat and hard place to reduce noise compressor does not work Frost protection starts Wait for 3 minutes until the temperature is lowered and then restart the machine Overheat...

Page 29: ...ipment should be disposed at the end of its life separately from your household waste There are separate collection systems for recycling in the EU For more information please see contact the local au...

Reviews: