M.FDK44.1-00 12/03/2015 

1. SAFETY  WARNINGS

This    dehumidifier  must  be  always  connected  using  earthed  electrical  plugs  as  required  for  all  electrical 
appliances;  Company  declines  any  responsibility  for  any  danger  or  damage  whenever  this  norm  is  not 
complied with.

 

Any intervention on the machine using any instrument must be carried out only by a qualified technician. 

When  the  machine  is  connected with  a  power  socket,    it  must  be  in  vertical  position  and  any  rough  move 
must be avoided because it could cause some water to come into contact with  electrical parts; it is therefore 
recommended to remove the plug from the socket before moving around the dehumidifier; if any water may 
have been spread on the machine, following some rough handling of the same, then the dehumidifier must 
be turned off and can be started up again only after 8 hours. 
Correct Distance: this dehumidifier
 draws in the air from the back and lets out through the front side grille: 
therefore the back panel, which supports the air filter, must be kept at a minimum distance of 15 cm from the 
wall.

 

The dehumidifier, moreover, must not be set running in narrow areas, which do not allow a proper  diffusion 
in  the  room  of  the  air  coming  out  from  the  grille.  It  is,  instead,  allowed  to  set  the  machine  sides  near  the 
walls. 

This dehumidifier  has  been  designed   and   manufactured   in compliance with the strictest safety rules. 
Therefore, pointed  instruments (screw drivers, wool  needles or  similar  ones) are  not to be inserted in the 
grille or in the opening of  the   back  panel when it is opened to remove the filter. 

The  machine  must  not  be  cleaned  using  water.  To  clean  the  machine    use  a  wet  cloth.  Remember  to 
disconnect the plug from the socket before.  
The front panel should not be used to lay over it cloths or other things: it could cause damages or dangers. 
The  filter  should  be  cleaned  periodically  (normally  every  month),  but  in  dusty  rooms  it  should  be  cleaned 
more often (see chapter 7). Remember that when the filter is dirty, the air circulation and, consequently, the 
machine performance is reduced. 

2. PERTINENT TECHNICAL NORMS AND REGULATIONS

The dehumidifier has been designed and manufactured in conformity to all following European Norms and 

Regulations: 

 MACHINES NORMS (2006/42/CE - 17.05.2006) ; 

SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006/95/CE - 12.12.2006

ELECTROMAGNETIC COMPATIBILITY (EMC) – 2004/108/CE – 15.12.2004

It is hereby certified that this Dehumidifier conform to the: 

 IEC Regulations CEI-EN 60335-2-40, CEI-EN 55014-1, 55014-2. 

The machine is built according to RoHS European Norms: 

2011/65/UE year 2011 and CEI-EN 50581. 

GB

 

Summary of Contents for FDK44S

Page 1: ...DEUMIDIFICATORI DEHUMIDIFIERS FDK44S MANUALE D USO E MANUTENZIONE USE AND MAINTENACE MANUAL M FDK44 1 00 12 03 15...

Page 2: ...o di riacquisto Lo smaltimento abusivo del prodotto da parte dell utente comporta l applicazione delle sanzioni amministrative di cui al D Lgs n 22 1997 art 50 e seg del D Lgs n 22 1997 INFORMATION FO...

Page 3: ...li laterali alle pareti senza creare difficolt al regolare funzionamento Questo deumidificatore costruito rispettando le pi severe norme di sicurezza Non si devono peraltro inserire oggetti appuntiti...

Page 4: ...tato consente il funzionamento del deumidificatore quando l umidit in ambiente pi elevata del livello desiderato Una scheda elettronica gestisce lo sbrinamento ed impedisce dannose partenze ravvicinat...

Page 5: ...el filtro che va eseguita con frequenza variabile a seconda della polverosit dell ambiente e della quantit di ore al giorno di effettivo funzionamento dell apparecchio Orientativamente per un uso norm...

Page 6: ...oming out from the grille It is instead allowed to set the machine sides near the walls This dehumidifier has been designed and manufactured in compliance with the strictest safety rules Therefore poi...

Page 7: ...the humidity his higher than the preset level An electronic circuit controls the defrosting and prevents the compressor repeated starts within too short a time by delaying each new start Machines prov...

Page 8: ...INTENANCE AIR FILTER CLEANING The only required periodical maintenance is the cleaning of the filter once every month or more often if the enviroment is very dusty or the dehumidifier is working for m...

Page 9: ...relative 35 99 Capacit di condensazione nominale a 32 C 92 44 l g Peso 34 kg Dimesioni LxDxH 580x360x420 Tensione 230 1 50 Specifications Rated Average Power Consumption at 20 C 60 R H 660 W Max Absor...

Page 10: ...10 M FDK44 1 00 12 03 2015 ELECTRONIC CARD 2 F1 3 ACL 5 LE2 6 LE1 4 LE3 1 ACN M1 ev M2 fan...

Page 11: ...ettrici da usare in Bassa Tensione 2004 108 CE del 15 Dicembre 2004 in materia di Compatibilit Elettromagnetica 2006 42 CE del 17 maggio 2006 in materia di sicurezza delle macchine La conformit dichia...

Page 12: ...safety and electro magnetic compatibility to European Norms and Regulations MACHINES NORMS 2006 42 CE 17 05 2006 SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006 95 CE 12 12 2006 ELECTROMAGNETIC C...

Reviews: