CAUTION

* It is intended for adult indoor use only. Sensitive people, including pregnant women 

pre-eclamptic patients, patients who implanted medical electronic instruments and have atrial 

fibrillation (AF), premature ventricular beats and peripheral arterial disease (PAD), should avoid 

using the unit whenever possible. If you need, please consult professional doctor.

* This device is intended for non-invasive measuring and monitoring of arterial blood pressure. It is

not intended for use on extremities other than the arm or for functions other than obtaining a

blood pressure measurement.

* Please use the device under specified environment by user manual, otherwise the accuracy of the

device will be influenced.

* Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood

pressure. Please start or end medical treatment basing solely on physician’s treatment advice.

* If you  are taking medication, consult your physician to determine the most appropriate time for

your measurement. Never change a prescribed medication without your physician’s consent.

* This unit is not suitable for continuous monitoring during medical emergencies or operations.

After the cuff inflated long time, the patient’s arm and fingers will be blood supply insufficiency,

anaesthesia, distending pain and ecchymosis. 

* If the pressure of the cuff exceeds 40 kPa (300 mmHg), the unit will automatically deflate. If the

cuff don’t deflate when its pressure exceeds 40 kPa (300 mmHg), detach the cuff from the arm 

and press the START/STOP button to stop inflation.

* Do not use the monitor under the conditions of strong electromagnetic field (e.g. medical RF

equipment) that radiates interference signal or electrial fast transient/ burst signal.

* The device is not AP/APG equipment. It is not suitable for use in the presence of a flammable

anesthetic mixture with air (or oxygen, nitrous oxide).

* Please keep the unit out of reach of infants, children or pets, since inhalation or swallowing of

small parts is dangerous or even fatal.

* Please use ACCESSORIES and detachable parts specified / authorised by MANUFACTURER.

Otherwise, it may cause damage to the unit or danger to the user / patient.

* The patient is an intended operator. The patient can measure, transmit data and charge battery

under normal circumstances and maintain the device and its accessories according to the user

manual.

* The blood pressure monitor, its adaptor, and the cuff are suitable for use within the patient

environment. If you are allergic to dacron or plastic, please don’t use this device.

* The device is not intended for PATIENT transport outside a healthcare facility.

*This device cannot be used with HF surgical equipment at the same time.

 

 

 

 

* The adaptor is specified as a part of ME equipment.

INTRODUCTION

INTRODUCTION

4

LCD Display Signal

Systolic 

Blood Pressure

High blood pressure

Diastolic 

Blood Pressure

Low blood pressure

Pulse

beat/minute

Unit

Measurement unit of blood pressure

Memory Query

Recalling the history records

Low Battery

Low battery and please charge the power.

IHB Detector

Irregular Heartbeat Detector

5

* If Luer lock connectors are used in the construction of tubing, there is a possibility that they might 

be inadvertently connected to intravascular fluid systems, allowing air to be pumped into a blood 

vessel.

* The device is not suitable for public use.

* The adapter insulates the device from the main supply. Do not position the plug in a position 

where it is difficult to disconnect from the supply mains.

* Be careful to strangulation due to cables and hoses, particularly due to excessive length.

Current time

Shocking reminder

Data pending to 

transmit

Year/Month/Day(Hour:Minute)

Shocking will result in inaccurate

Measurement data stored in the device

Data transmitting

Data transmission succeeds.

User ID

Start measurement for selected user,

and transmit the measuring result

Heartbeat

Heartbeat Detection during the 

measurement

Summary of Contents for LS808-B

Page 1: ...ing No 12 Huizhan East Rd Torch Development District Zhongshan Guangdong 528437 China Airon Wireless products Airon Wireless system is a series of products which provide you with a good overview of so...

Page 2: ...Why does my blood pressure fluctuate throughout the day Why the blood pressure I get from the hospital is different from home If the result is the same if measuring on the right arm TROUBLESHOOTING S...

Page 3: ...READ Symbol for COMPLIES WITH MDD 93 42 EEC REQUIREMENTS Symbol for MANUFACTURER Symbol for SERIAL NUMBER Symbol for TYPE BF APPLIED PARTS Symbol for DIRECT CURRENT Symbol for ENVIRONMENT PROTECTION...

Page 4: ...r or oxygen nitrous oxide Please keep the unit out of reach of infants children or pets since inhalation or swallowing of small parts is dangerous or even fatal Please use ACCESSORIES and detachable p...

Page 5: ...the authorized maintenance personel If measured three times per day and the battery is fully charged it can be used for about 20 days 3 Storge and use the blood pressure monitor at the cool dry and v...

Page 6: ...START 2 As pictured in the right the blinking numeral representing HOUR Press Query button to change the numeral Each press will increase the numeral by one in a cycling manner 3 Press User 1 button...

Page 7: ...T BEFORE YOU START 5 Repeat step 2 and 3 to confirm MONTH DAY and YEAR 6 Repeat step 2 and 3 to confirm the measurement unit 7 After confirming the measurement unit the LCD will display dOnE and the m...

Page 8: ...Hypertension patient Bare your arm or wear tights only when starting measurement Sit comfortably with legs uncrossed feet flat on the floor back and arm supported The central of the cuff should mainta...

Page 9: ...off otherwise it will turn off with one minute Tips A When finish the whole measurement press another user button the blood monitor will begin measuring again B Maximum 60 records are both for user 1...

Page 10: ...ry records 4 When in the memory mode press the User 1 button to recall the measurement history of User 1 or press the User 2 button to recall the measurement history 5 When no history stored for the s...

Page 11: ...atient too frequent and consecutive multiple measurements the application of the CUFF and itspressurization on any arm where intravascular access or therapy or an arterio venous A V shunt is present I...

Page 12: ...ng Dust environment may affect the performance of the unit Please use the soft cloth to remove the dirt of the device and cuff before and after use 5 Calibration The manufacturer does not require such...

Page 13: ...sician could tell whether your blood pressure value has reached a dangerous point The blood pressure classification published by World Health Organization WHO and International Society of Hypertension...

Page 14: ...e Blue LCD with White Backlight V A 86 5mm L x24mm W Measurement mode Oscillographic testing mode Measurement range Accuracy Normal working condition Storage transportation condition Measurement perim...

Page 15: ...used in the home healthcare environment IEC EN 80601 2 30 2009 Medical electrical equipment Part 2 30 Particular requirements for the basic safety and essential performance of automated noninvasive s...

Page 16: ...munications equipment such as wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance d...

Reviews: