43
Pan detection
The pan detection ensures a perfect safety. The induction doesn’t work:
•
If there is no pan on the heating zone or if this pan is not adapted to the induction. In this
case it is impossible to increase the power and the display shows [ U ]. This symbol
disappears when a pan is put on the heating zone.
•
If the pan is removed from the heating zone the operation is stopped. The display shows
[ U ]. The symbol [ U ] disappears when the pan is put back to the heating zone. The
cooking continues with the power level setted before.
After use, switch the heat element off: don’t let the pan detection [ U ] active
Residual heat indication
After the switch off of a heating zone or the complete stop of the hob, the heating zones are still
hot and indicates [ H ] on the display.
The symbol [ H ] disappears when the heating zones may be touched without danger.
As far as the residual heat indicators are on light, don’t touch the heating zones and don’t put any
heat sensitive object on them.
There are risks of burn and fire.
Booster function
The booster function [ P ] grants a boost of power to the selected heating zone.
If this function is activated the heating zones works during 5 minutes with an ultra high power.
The booster is foreseen for example to heat up rapidly big quantities of water, like nuddles cooking.
•
Start up / Stop the booster function:
Action
Control panel
Display
Zone selection
Press selection key from the zone
[ 0 ]
Increase power
Press key [ + ]
[ 1 ] to [ 9 ]
Start up the booster
Press key [ + ]
[ P ] during 5 min
Stop the booster
Press key [ - ]
[ 9 ]
•
Power management :
The hole cooking hob is equipped by a maximum of power. When the booster function is
activated, and not to exceed the maximum power, the electronic system orders to reduce
automatically the power level of an other heating zone. The display is blinking on [ 9 ] during a
few seconds and then shows the maximum of power allowed ( [ 6 ] or [ 8 ] ).
Heating zone selected
The other heating zone: (example: power level 9)
[ P ] is displayed
[ 9 ] goes to [ 7 ] depending the type of zone