User manual – Controller CP Touch 

Controller description

The CP Touch controller can be connected to DUPLEX units fitted with an RD5 control 
board. The CP Touch provides full control for these units, i.e. service parameter 
settings (password protected) as well as user settings. It has a manual mode, allowing 
the user to choose directly the operating mode of the unit, and a weekly mode 
controlling the unit according to a weekly program. The software version is also 
shown in the user setting of the controller (

 6.8). 

Note: The CP Touch controller’s commissioning and connection to a DUPLEX 

units may only be done by a specialist company with up-to-date training certification 
for DUPLEX units with RD5 controls.    

Installation 

First, mount the controller on the designated location on the wall. 

It can be mounted on a standard electrical box with a hole spacing of 68mm. 

The box can be clipped on from one 

direction only 

Cross-section of the wall with 
the controller box 

Step 1

: Before installation 

dismantle the controller, 
removing its front from its 
back. 

Step 2: 

Place the back on the 

designated spot on the wall and fix it 
using screws. 

Step 3: 

Clip the front with display 

onto the fixed back. 

68mm

→●←

   Press here 

Summary of Contents for CP Touch

Page 1: ...DATUM N ZEV SPOLE NOSTI Adresa spole nosti USER MANUAL CONTROLLER CP Touch Version 03 EN Issue 06 11 2018 Code M_19_V03_EN_2018_11...

Page 2: ...tween HS NHS 11 6 1 3 HS NHS temperature 11 6 1 4 Current season 11 6 2 Control settings 11 6 2 1 Blocking input IN1 No HS NHS 11 6 2 2 Blocking input IN2 No HS NHS 12 6 2 3 Heating hysteresis 12 6 2...

Page 3: ...roller 6 8 Note The CP Touch controller s commissioning and connection to a DUPLEX units may only be done by a specialist company with up to date training certification for DUPLEX units with RD5 contr...

Page 4: ...n follow the wiring diagram located in the lid of the AHU s cabinet If there more controllers connected they must be in a series as shown in Fig 1 Note According to the diagram up to four controllers...

Page 5: ...roller in the series must be terminated with a T CAN jumper Number of controllers connected A1 A2 T CAN 1 0 0 1 0 0 0 2 0 1 0 0 0 2 0 0 3 0 1 0 0 0 2 0 0 3 0 0 4 Table 1 0 Unconnected jumper Connected...

Page 6: ...iting for communication with the control board if this takes more than 3 minutes the screen switches to Communication Error Main screen appears but data are 0 The controller s application has loaded p...

Page 7: ...program Temporary manual change of the weekly program Group 3 Party Holiday mode active Bank holiday mode active Group 4 Symbol indicates heating Symbol indicates cooling Group 5 Active alarm symbol y...

Page 8: ...s icon Service settings accessible after entering a password any data in the service settings may be edited only by an authorized service technician Table 5 5 Blocks on the main screen 5 1 Power block...

Page 9: ...en input status changes Dn INk Ventilation The unit is ventilating at a power level set or higher as set by an external input which is active Night pre cooling The unit is in OFF mode If starts ventil...

Page 10: ...gram If that is the case the zone requirement is generated by a closed input D1 D4 and parameters set for one of these inputs Note Zone texts can be set for more information see 6 6 The initial zone d...

Page 11: ...than Temperature HS NHS the Non heating season is selected automatically If outside temperature is lower than Temperature HS NHS and at the same time room temperature is higher than the required tempe...

Page 12: ...ture difference compared to the temperature required to start heating The setting range is between 0 1 C and 5 C 0 1 C steps 6 2 4 Cooling hysteresis To set a temperature difference compared to the te...

Page 13: ...ding to the weekly program and should be switched temporarily to economy mode for example for a week when there is no occupancy in the house When the parameters set for the Holiday Party function have...

Page 14: ...is activated and deactivated according to the start and end times set After pressing this button changes to the Deactivate button 6 4 Weekly program setting The weekly program is set separately for th...

Page 15: ...and to move between all eight intervals days The weekly program allows copying and pasting the settings of a given day as follows Into each day of the week Into selected days Into Bank holidays Schoo...

Page 16: ...t the basic parameters of the display Backlight setting The display backlight is changed using the setting arrows see Fig 16 Internet time sync Time sync with the internet is done by checking this opt...

Page 17: ...summer and standard time 6 8 SW information unit type configuration specifications version Information on the type of the unit its manufacturing number and the version of the control software 7 Filte...

Page 18: ...dition usually lasts for several minutes and the unit goes back to normal operation after the heat recovery exchanger has been defrosted Temperature sensor downstream TA2 external heater Communication...

Page 19: ...unit from power supply and if there is no risk of overheating in the room fire etc reconnect it Communication error Breakdown of communication between the controller and AHU Check whether the cable b...

Page 20: ...ss damper is primarily controlled by setting the required temperature Tp and cannot be controlled manually 9 3 Circulation damper The circulation damper also known as the mixing damper is used for mix...

Reviews: