1. Overview
AirLive SP-101 User Manual
8
caution
5
Restore
switch state
mode
1
0-2
1
0: Switch off
1: Last switch
state 2 : Switch
on
6
Mode of
Switch Off
function
1
0-1
1
1.
: Disable
2.
: Enable
7
LED
indication
mode
1
1-3
1
1 : Show switch
state 2 : Show
night mode 3 :
One flash mode
8
Auto off timer
2
0-0x7FF
F
1s
0
0 : Disable auto
off function
1-0x7FFF : 1s
~32767s
9
RF off
com-mand
mode
1
0-3
0
0 : Switch off 1 :
Ignore
2 : Switch toggle
3 : Switch on
1.5.3.1.
Watt Meter Report Period
If the setting is configured for 1hour (set value =720), the Plug will report its instant power
consumption every 1 hour to Group1 node. The maximum interval to report its instant
power consumption is 45 hours (5s*32767/3600=45hr).
1.5.3.2. KWH
Meter
Report Period
If the setting is configured for 1hour (set value =6), the Plug will report its Accumulated
Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report
its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55
days).
1.5.3.3. Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the setting
value is 1300, when the load current of Relay1 over this value, Plug will send current meter
report to warn the Group1 node, the Range of the setting value is from 10 to 1300, and the
default value is 1300.
1.5.3.4. Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the setting value
is 10000, when the Accumulated Power Consumption of Relay1 over this value, Plug will
send KWH meter report to warn the Group1 node, minimum value is 1KWh and default
value is 10000 kWh.
1.5.3.5. Restore switch state mode
Whenever the AC power return from lost, Plug will restore the switch state which could be
SWITCH OFF
、
LAST SWITCH STATE
、
SWITCH ON. The default setting is LAST SWITCH
STATE.