background image

 

INTERTEK TESTING SERVICES 

 

Report No: SZ12060359-1 
FCC ID: ZGIDA065 
TRF No.: FCC 15C_TX_b

 

 

1

 

 
 

 

EXHIBIT 1 

 
 

GENERAL DESCRIPTION 

Summary of Contents for DB038

Page 1: ...are relevant only to the sample tested This report by itself does not imply that the material product or service is or has ever been under an Intertek certification program For Terms And Conditions of the services it can be provided upon request The evaluation data of the report will be kept for 3 years from the date of issuance TRF No FCC 15C_Tx_b Intertek Testing Services Shenzhen Ltd Kejiyuan B...

Page 2: ...BITS INTRODUCTION EXHIBIT 1 General Description EXHIBIT 2 System Test Configuration EXHIBIT 3 Emission Results EXHIBIT 4 Equipment Photographs EXHIBIT 5 Product Labelling EXHIBIT 6 Technical Specifications EXHIBIT 7 Instruction Manual EXHIBIT 8 Miscellaneous Information EXHIBIT 9 Test Equipment List ...

Page 3: ...nt requested per 47 CFR 0 457 d 1 ii Yes No X If yes defer until date Company Name agrees to notify the Commission by date of the intended date of announcement of the product so that the grant can be issued on that date Transition Rules Request per 15 37 Yes No X If no assumed Part 15 Subpart C for intentional radiator the new 47 CFR 10 1 11 Edition provision Report prepared by Billy Li Intertek T...

Page 4: ...Support Equipment List and Description 6 3 0 Emission Results 8 3 1Radiated Test Results 9 3 1 1 Field Strength Calculation 9 3 1 2 Radiated Emission Configuration Photograph 10 3 1 3 Radiated Emissions 10 3 1 4 Transmitter Spurious Emissions Radiated 12 3 2 Conducted Emission at Mains Terminal 14 3 2 1 Conducted Emissions Configuration Photograph 14 3 2 2 Conducted Emissions 14 4 0 Equipment Phot...

Page 5: ...d Photos conducted photos pdf Test Report Bandedge Plot bandedge pdf Test Report 20dB BW Plot bw pdf External Photo External Photo external photos pdf Internal Photo Internal Photo internal photos pdf Block Diagram Block Diagram block pdf Schematics Circuit Diagram circuit pdf Operation Description Technical Description descri pdf ID Label Location Label Artwork and Location label pdf User Manual ...

Page 6: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 1 EXHIBIT 1 GENERAL DESCRIPTION ...

Page 7: ... to the user manual The Model ZFM M80US is the same as the Model DB038 in hardware aspect The models are difference in plastic colour packaging and marketing purpose only The Models DA065 ZFM 80US are the same as the Models DB038 in hardware aspect of RF portion The difference between the models is as below DB038 ZFM M80US with power meter function DA065 ZFM 80US without power meter function Anten...

Page 8: ...ns were performed in the semi anechoic chamber only to determine the worst case modes All radiated tests were performed at an antenna to EUT distance of 3 meters unless stated otherwise in the Justification Section of this Application 1 4 Test Facility The Semi Anechoic chamber and shielding room used to collect the radiated data and conducted data are Intertek Testing Services Shenzhen Ltd Kejiyu...

Page 9: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 4 EXHIBIT 2 SYSTEM TEST CONFIGURATION ...

Page 10: ...e flushed with the rear of the table The equipment under test EUT was configured for testing in a typical fashion as a customer would normally use it The EUT was placed on a turn table which enabled the engineer to maximize emissions through its placement in the three orthogonal axes 2 2 EUT Exercising Software The EUT exercise program provided by client used during radiated and conducted testing ...

Page 11: ...urement Uncertainty When determining the test conclusion the Measurement Uncertainty of test has been considered 2 6 Support Equipment List and Description Description Manufacturer Model No Lighting Load Airline Mechanical Co Ltd 1800W 120Vac 60Hz 15A External Switch Airline Mechanical Co Ltd N A ...

Page 12: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 7 EXHIBIT 3 EMISSION RESULTS ...

Page 13: ... ID ZGIDA065 TRF No FCC 15C_TX_b 8 3 0 Emission Results Data is included worst case configuration the configuration which resulted in the highest emission levels A sample calculation configuration photographs and data tables of the emissions are included ...

Page 14: ...ifier Gain in dB In the radiated emission table which follows the reading shown on the data table may reflect the preamplifier gain An example of the calculations where the reading does not reflect the preamplifier gain follows FS RA AF CF AG Assume a receiver reading of 62 0 dBµV is obtained The antenna factor of 7 4 dB and cable factor of 1 6 dB is added The amplifier gain of 29 dB is subtracted...

Page 15: ...guration photograph is saved with filename radiated photos pdf 3 1 3 Radiated Emissions The data on the following page lists the significant emission frequencies the limit and the margin of compliance Numbers with a minus sign are below the limit Worst Case Radiated Emission at 96 074 MHz Judgement Passed by 5 3 dB TEST PERSONNEL Sign on file Andy Yan Engineer Typed Printed Name July 14 2012 Date ...

Page 16: ...396 302 38 0 20 0 16 5 34 5 46 0 11 5 Vertical 36 016 37 2 20 0 14 4 31 6 40 0 8 4 Vertical 96 074 50 0 20 0 8 2 38 2 43 5 5 3 Vertical 444 322 35 7 20 0 17 7 33 4 46 0 12 6 NOTES 1 Quasi Peak detector is used except for others stated 2 All measurements were made at 3 meters Harmonic emissions not detected at the 3 meter distances were measured at 0 3 meter and an inverse proportional extrapolatio...

Page 17: ...s Radiated The data on the following page lists the significant emission frequencies the limit and the margin of compliance Numbers with a minus sign are below the limit Worst Case Radiated Emission at 1816 840 MHz Judgement Passed by 7 9 dB TEST PERSONNEL Sign on file Andy Yan Engineer Typed Printed Name July 14 2012 Date ...

Page 18: ...V m dBµV m dB Horizontal 1816 840 55 7 36 8 27 2 46 1 54 0 7 9 Horizontal 2725 260 49 3 36 7 29 6 42 2 54 0 11 8 Horizontal 3633 680 49 8 36 5 31 8 45 1 54 0 8 9 Notes 1 Quasi Peak detector is used for frequency up to 1GHz and Peak detector is used for frequency over 1GHz 2 All measurements were made at 3 meter Harmonic emissions not detected at the 3 meter distance were measured at 0 3 meter and ...

Page 19: ...ons Configuration Photograph For electronic filing the worst case conducted emission configuration photograph is saved with filename conducted photos pdf 3 2 2 Conducted Emissions Worst Case Neutral Conducted Configuration at 24 018 MHz Judgement Passed by 4 7 dB margin TEST PERSONNEL Sign on file Andy Yan Engineer Typed Printed Name July 14 2012 Date ...

Page 20: ...on Mains QP FCC Part 15 Class B Voltage on Mains AV Result Table QP Frequency MHz QuasiPeak dBμV Line Corr dB Margin dB Limit dBμV 0 202000 43 8 L1 9 6 19 7 63 5 0 338000 41 2 L1 9 6 18 1 59 3 1 178000 29 8 L1 9 7 26 2 56 0 1 846000 26 8 L1 9 7 29 2 56 0 12 010000 38 6 L1 10 1 21 4 60 0 24 018000 41 6 L1 10 6 18 4 60 0 Result Table AV Frequency MHz Average dBμV Line Corr dB Margin dB Limit dBμV 0 ...

Page 21: ...oltage on Mains QP FCC Part 15 Class B Voltage on Mains AV Result Table QP Frequency MHz QuasiPeak dBμV Line Corr dB Margin dB Limit dBμV 0 202000 44 2 N 9 6 19 3 63 5 0 338000 40 6 N 9 6 18 7 59 3 1 190000 34 3 N 9 8 21 7 56 0 1 850000 31 1 N 9 8 24 9 56 0 12 010000 43 0 N 10 1 17 0 60 0 24 018000 49 6 N 10 7 10 4 60 0 Result Table AV Frequency MHz Average dBμV Line Corr dB Margin dB Limit dBμV 0...

Page 22: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 17 EXHIBIT 4 EQUIPMENT PHOTOGRAPHS ...

Page 23: ... SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 18 4 0 Equipment Photographs For electronic filing the photographs of the tested EUT are saved with filename external photos pdf internal photos pdf ...

Page 24: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 19 EXHIBIT 5 PRODUCT LABELLING ...

Page 25: ...EK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 20 5 0 Product Labelling For electronic filing the FCC ID label artwork and the label location are saved with filename label pdf ...

Page 26: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 21 EXHIBIT 6 TECHNICAL SPECIFICATIONS ...

Page 27: ... Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 22 6 0 Technical Specifications For electronic filing the Block diagram and schematics of the tested EUT are saved with filename block pdf and circuit pdf respectively ...

Page 28: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 23 EXHIBIT 7 INSTRUCTION MANUAL ...

Page 29: ...C ID ZGIDA065 TRF No FCC 15C_TX_b 24 7 0 Instruction Manual For electronic filing a preliminary copy of the Instruction Manual is saved with filename manual pdf This manual will be provided to the end user with each unit sold leased in the United States ...

Page 30: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 25 EXHIBIT 8 MISCELLANEOUS INFORMATION ...

Page 31: ...EK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 26 8 0 Miscellaneous Information This miscellaneous information includes details of the measured bandedge and the test procedure ...

Page 32: ...n section 15 209 It fulfils the requirement of 15 249 d Peak Measurement Bandedge compliance is determined by applying marker delta method i e Bandedge Plot i Left bandedge Peak Resultant field strength Fundamental emissions peak value delta from the bandedge plot 85 7dBµv m 54 0dB 31 7dBµv m ii Right bandedge Peak Resultant field strength Fundamental emissions peak value delta from the bandedge p...

Page 33: ... 15 215 c the 20dB bandwidth of the emission was contained within the frequency band designated mentioned as above which the EUT operated The effects if any from frequency sweeping frequency hopping other modulation techniques and frequency stability over excepted variations in temperature and supply voltage were considered Figure 8 1 Bandwidth ...

Page 34: ...T are manipulated to find the configuration resulting in maximum emissions The EUT is adjust through all three orthogonal axes to obtain maximum emission levels The antenna height and polarization are varied during the testing to search for maximum signal levels Above 1000 MHz peak detector is used for measurement On any frequency or frequencies below or equal to 1000 MHz the limits shown are base...

Page 35: ...scribed in ANSI C63 4 2009 The IF bandwidth used for measurement of radiated signal strength was 10 kHz for emission below 30 MHz and 120 kHz for emission from 30 MHz to 1000 MHz Above 1000 MHz a resolution bandwidth of 1 MHz is used Transmitter measurements are normally conducted at a measurement distance of three meters However to assure low enough noise floor in the restricted bands and above 1...

Page 36: ...INTERTEK TESTING SERVICES Report No SZ12060359 1 FCC ID ZGIDA065 TRF No FCC 15C_TX_b 31 EXHIBIT 9 TEST EQUIPMENT LIST ...

Page 37: ... R S FSP 30 101148 11 Mar 12 11 Mar 13 SZ067 14 Highpass Filter Mini Circuits VHF 1500 1022 11 Jun 12 11 Jun 13 SZ181 04 Preamplifier Agilent 8449B 3008A02474 11 Mar 12 11 Mar 13 SZ188 01 Anechoic Chamber ETS RFD F A 100 4102 03 Mar 12 03 Mar 13 SZ062 02 RF Cable RADIALL RG 213U 17 Mar 12 17 Sep 12 SZ062 06 RF Cable RADIALL 0 04 26 5GHz 01 Nov 11 01 Nov 12 SZ062 12 RF Cable RADIALL 0 04 26 5GHz 25...

Reviews: