Repair
12
3A0413B
7.
While supporting spring guide (16) to
prevent bending needle, loosen
setscrews (17). Remove spring guide
(16).
8.
Remove needle (2c). Unscrew seal
retainer (2d). Remove seal (2e).
Cleaning
Clean all parts and cavities thoroughly with
a compatible solvent. Dry with a rag or com-
pressed air. Replace any parts that are worn
or damaged.
Reassemble
1.
Lightly grease inner cavities of fluid
housing (22). Install small seal (2e) so
lips face into fluid housing cavity. Install
seal retainer (2d) and torque to 30-40
in-lb (3.4-4.5 N•m).
2.
Lightly grease small end of needle (2c).
Guide (2c) into large end of fluid housing
(22).
16
16
ti15240a
ti15241a
16
17
1
2
3
Lips of seal must face into housing
Grease inner cavity of housing
Torque to 20-30 in-lb (3.4-4.5 N•m)
22
2e
2d
1
2
3
ti15242a
ti15243a
2c
22