AirKing AK150H Important Instructions & Operating Manual Download Page 15

Tous les modèles

#

Qté. Description

# de pièce de 

remplacement

1

4

Traverses de Montage

5S1299002

2

1

Assemblée de collier en métal de 6 po

5S5299100

3

2

Ressorts de la grille

5S1202046

4

1

Bride du plafond

5S1202050

5

2

Canal de montage

5S1202123

6

1

Assemblée de la Soufflante

5S2239008

Particularités des modèles E80S, E110S, E130S

#

Qté. Description

# de pièce de 

remplacement

7

1

Grille

5S1202048

9

1

Assemblée du compartiment du fil - E80S

5S1239858

1

Assemblée du compartiment du fil - E110S

5S1239892

1

Assemblée du compartiment du fil - E130S

5S1239859

Particularités des modèle AK150LS

#

Qté. Description

# de pièce de 

remplacement

7

1

Grille

5S1202048

8

1

Assemblée du compartiment du fil

5S1239860

Particularités des modèle AK150H

#

Qté. Description

# de pièce de 

remplacement

7

1

Grille

5S1202048

12

1

Assemblée du compartiment du fil

5S1202640

10

1

Bouton

5S1299802

11

1

Compartiment du capteur d’humidité

5S1239826

www.airkinglimited.com

6728035 Rev. R 12-18

15 of 16

Particularités des modèles E80SG, E130SG

#

Qté. Description

# de pièce de 

remplacement

16

1

Assemblée du compartiment du fil - E80SG

5S1239861

Assemblée du compartiment du fil - E130SG

5S1239862

13

1

Assemblée de Grille

5S1239115

17

1

Détecteur de mouvement

5S1999100

Particularités des modèles E80SH, E130SH

#

Qté. Description

# de pièce de 

remplacement

7

1

Grille

5S1202048

15

1

Assemblée du compartiment du fil - E80SH

5S1239863

1

Assemblée du compartiment du fil - E130SH

5S1239864

9

1

Bouton

5S1299802

11

1

Compartiment du capteur d’humidité

5S1239826

Particularités des modèles E80SGH, E130SGH

#

Qté. Description

# de pièce de 

remplacement

14

1

Assemblée du compartiment du fil - E80SGH

5S1239874

Assemblée du compartiment du fil - E130SGH

5S1239875

10

1

Bouton

5S1299802

11

1

Compartiment du capteur d’humidité

5S1239826

13

1

Assemblée de Grille

5S1239115

17

1

Détecteur de mouvement

5S1999100

DIAGRAMME DES PIÈCES DE REMPLACEMENT

2

1

3

7

1

6

4

5

8

10

14

11

10

11

12

10

15

11

16

13

17

9

Summary of Contents for AK150H

Page 1: ...fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equip...

Page 2: ...e previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6728035 Rev R 12 18 2 of 16 SECTION 4 Ducting NOTE 6 OR L...

Page 3: ...ording to all local and national codes Humidity Sensing Models 4a For proper operation the humidity sensing fan will require a 3 way switch not included Run wiring between the fan and the switch locat...

Page 4: ...ompartment cover Plug the 3 pin quick connect motor cord into the shorter end of the included harness then into the receptacle located on the top of the wire compartment cover These cords will only fi...

Page 5: ...he fan will operate If the room is occupied longer the fan will continue to run until the room is vacated and the occupancy time delay has elapsed 2b Locate the motion sensor on the fan s grill and pr...

Page 6: ...does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AN...

Page 7: ...rill 5S1202048 12 1 Wire Compartment Assembly 5S1202640 10 1 Knob 5S1299802 11 1 Humidity Sensor Compartment 5S1239826 Specific to Models E80SG E130SG Qty Description Replacement Part 16 1 Wire Compar...

Page 8: ...www airkinglimited com 6728035 Rev R 12 18 8 of 16 NOTES...

Page 9: ...combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et...

Page 10: ...des rails aux solives Figure 1 www airkinglimited com 6728035 Rev R 12 18 10 of 16 SECTION 4 Conduits NOTE UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTI...

Page 11: ...pr sents REMARQUE L unit doit tre mise la terre selon les codes locaux et nationaux Mod les avec d tection d humidit 4a Pour un bon fonctionnement le ventilateur de d tection d humidit exigera un inte...

Page 12: ...la vis qui fut enlev e pr c demment SECTION 6 Compl tion de l installation 1 Il est recommand d utiliser un scellant appropri pour le contact avec les mat riaux de construction actuels et pour les bes...

Page 13: ...git d un minimum de temps que le ventilateur fonctionne Si la salle est occup e plus longtemps le ventilateur continuera de fonctionner jusqu ce que la salle est vide et le temps du d lai d occupation...

Page 14: ...manipulation ou op ration de dommages d exp dition d abus de mauvaise utilisation de r paration faite ou tent es non autoris es Cette garantie ne couvre pas les co ts d exp dition pour le retour des p...

Page 15: ...ompartiment du capteur d humidit 5S1239826 www airkinglimited com 6728035 Rev R 12 18 15 of 16 Particularit s des mod les E80SG E130SG Qt Description de pi ce de remplacement 16 1 Assembl e du compart...

Page 16: ...www airkinglimited com 6728035 Rev R 12 18 16 of 16 REMARQUE...

Reviews: