1 – Pedal mount
Installation Procedures
AG250-503
LIST OF PARTS ENCLOSED
Please read the instructions once through before starting.
PEDAL INSTALLATION INSTRUCTIONS
1 – Top mounting plate
2.
2 – #10x3/4 length mounting screws
2 – #10x1 length mounting screws
The AG250-503, in combination with the
AG250-003 valve, provides a hands-free
faucet operation. The valve is ordered
separately.
AG250-003
Cold/Hot Potable Water
Electrical Valve
AG250-503
Pedal
Place top mounting plate at the edge of the
cabinet and mark location of mounting
screws.Drill two holes for #10 screws.
(13/64-inch).
Drill hole 3/8-inch under the cabinet plate for
cable connection to the valve. (FIG.1)
1.
FIG. 1
3/8" Diameter
Openings for
#10 screws
Pass cable from the AG250-503 pedal through the
3/8-inches opening under the cabinet plate and connect
it to AG250-003 valve installed inside the cabinet. (FIG.2)
FIG. 2
FIG.3
Use provided #10 screws (1-inch or
3/4-inches) to attach the pedal. (FIG.3)
-OVER-
3.
Summary of Contents for Tap-a-tap AG250-503