 80000110 Issue 4 

– 05/13                                                                                                                                                  

 

 

 

 

Installation and Operating Guide 

LOOVENT eco

 Centrifugal Fans

 

 

 
                                                                 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  Economical to operate 

  Very quiet running fan 

  Low SFP 

  Compact design 

  Longer life Ball Bearing Motor 

  Simple replacement of existing Loovent 

 

 
 
 

Read before commencing installation. Please leave these 
instructions for the occupier 

 

LOOVENT eco T

 – Timer (

72684305)

 

LOOVENT eco HT

 – Humidity Timer (

72684306)

 

LOOVENT eco MST

 – Motion Sensor Timer (

72684307)

 

LOOVENT eco dMEV

 – Continuous Ventilation (

72684308

)

 

 
 

Summary of Contents for LOOVENT eco T

Page 1: ... SFP Compact design Longer life Ball Bearing Motor Simple replacement of existing Loovent Read before commencing installation Please leave these instructions for the occupier LOOVENT eco T Timer 72684305 LOOVENT eco HT Humidity Timer 72684306 LOOVENT eco MST Motion Sensor Timer 72684307 LOOVENT eco dMEV Continuous Ventilation 72684308 ...

Page 2: ... remotely by means of a switched live connection from a light or door switch The dMEV model uses the switched live to initiate boost mode All models feature a momentary pull cord switch as a manual boost override no click will be heard when you pull this cord The fan has an ingress protection rating of IPx5 and is suitable for mounting in Zone 1 or 2 with a 30mA RCD as defined in Section 701 BS716...

Page 3: ...d slightly and slide to the right to release from the two lugs in the base Figure 7 Recessing in the Wall The fan can be mounted landscape with the release buttons facing downwards or portrait with the buttons on the right hand edge The fan requires a 110mm diameter hole through the external wall lined with a 100mm internal diameter duct kit refer to Page 8 for accessories The internal wall requir...

Page 4: ... the pull cord is stowed This also means the Timer and Motion Sensor Timer versions become single speed fans L or H which should be selected at installation depending on the requirement The Humidity and dMEV versions remain 2 speed as they are automatically boosted by the humidity sensor and remote switch respectively Refer to the Electrical Installation section for wiring instructions and fitting...

Page 5: ...lations should be carried out by an approved electrician in accordance with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation The LOOVENT eco requires a 100 240V 50 60Hz supply and an external 3A fuse it is double insulated so therefore does not require an earth For fans mounted in Zones 1 2 as defined in section 701 BS71...

Page 6: ...LS AND CLEANING OF INTERNAL PARTS For safety This fan is fitted with a safety device which inhibits operation when the front cover is open However it is recommended that the fan is isolated from the power supply by switching the 3 pole isolator or 2 pole fused spur if the fan has no external switching before opening the front cover The fan must be isolated if the impeller module is to be removed e...

Page 7: ...ed with the Delay Start Boost in the OFF position Intermittent setting the switch to ON applies a 2 minute delay to the low speed ideal for quick visits It does not delay the Pull Cord override function Continuous setting the switch to ON will delay the timer function on boost speed by 2 minutes where the boost is activated by a remote switch It does not delay the Pull Cord override function Note ...

Page 8: ...nits for 3 YEARS from date of purchase against faulty material or workmanship Extended to 5 years when registered airflow com Warranty only covers the fan not the reinstallation of this if required In the event of any defective parts being found Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that the unit 1 Has been installed and used in a...