SELV 12V Fan Range 

Installation and Operating Guide 

iCON 15S  –  72683701 
iCON 30S  –  72683801 

Fan dimensions 

Page 2 of 16 

Airflow®  iCON®  SELV  range  are 

12V  DC 

powered

  Safety 

Extra  Low  Voltage

  fans.  Fans  are  available  in  two  model 

sizes and can be fitted to a wall or ceiling.  

iCON 15S -100mm axial fan 
iCON 30S -100mm mixed-flow fan 

The  iCON  SELV  range  can  be  used  as  a  simple  extract 
SELV  fan  operated  by  a  remote  switch  (standard)

, or can 

be  fitted  with  an  internal  control  module  to  give  a  range  of 
control options (which includes: timer, humidity, motion sensor, 
pull cord or combinations of these functions).  

These  optional  modules  are  available  separately  and  can  be 
fitted at the time of installation or retrofitted (see page 15).  

All  electrical  installation  must  be  carried  out  by  an  approved 
electrician  in  accordance  with  Approved  Document  Part  P  of 
U.K.  Building  Regulations  and  to  the  latest  IET  standards,  or 
the appropriate regulations in the country of installation.  

The  fan  requires  a  12V  DC  supply  (included  in  the  box), 
class III equipment

 (marked as stated in BS EN 60417).  

The  iCON  SELV  fan  range  is  IPX4  rated  and  therefore  it  is 
suitable  for  mounting  in  bathrooms  (incl.  zones  1  and  2),  toi-
lets, kitchens and utility rooms, as long as it is not exposed to 
water jets (i.e. can be installed 

above fixed shower head

).   

Switches  for  fans  shall  be  selected  and  sited  in  accordance 
with BS7671 (IET Wiring Regulations) or relevant.  

Important 

Do not place the ventilator near direct heat sources, e.g. radi-
ant heaters,

 

or where temperatures can exceed 40°C (104°F). 

Wiring with no control module fitted:

 

Recessing fans in the wall 

The 

iCON  15S

  requires  a  110mm  diameter  hole  through  the 

wall lined with a 100mm internal diameter duct. 

The 

iCON  30S

  requires  a  110mm  diameter  hole  through  the 

wall,  counter  bored  160mm  to  a  depth  of  80mm.  The  hole 
should be lined with a 100mm internal diameter duct.  

Surface mounting fans on the wall 

When surface mounting the iCON 30S the supplied mounting 
skirt should be used. 

The 

iCON  30S 

requires  a  110mm  diameter  hole  through  the 

wall lined with a 100 mm internal diameter duct. 

Ensure all vapour barriers are properly restored.  

Optional modules for iCON SELV 12V 

Wiring  and  installation  of  iCON  modules  can  be  found  in  the 
Instructions included within the module packaging. 

Wiring for control modules with external switching: 

Power Supply Unit (PSU, included in the box) 

The  power  supply  unit  requires  100-240V  50/60Hz  supply 
(class  II).  It  is  self  resetting  for  over  current  and  short  circuit 
protection. An external 3A fuse and 30mA RCD is required for 
each unit. The LED indicator shows the unit is switched on.  

The power supply unit must be fitted outside of wet zones

 

(usually  outside  of  the  room).  The  maximum  length  of  wire 
between  the  unit  and  the  fan  should  not  exceed  5  meters 
using  1.5mm

2

  wire.  Never  cover  the  power  supply  unit  with 

thermal insulation materials. 

iCON fans can  be recessed in a  wall  or  ceiling  (iCON 30S is 

also  supplied  with  surface  mounting  kit).  See  pages  8-10  for 

details.  

Always  ensure  free  running  of  the  fan  impeller  and  that  duct 

connections are not over tightened to the fan outlet spigot.  

Fix  the  sealed  grommet  supplied  into  the  cable  entry  hole. 

Pierce  the  grommet  to  allow  the  mains  cable  to  be  pulled 

through while maintaining the integrity of the seal.  

Airflow  Developments  recommends  that  rigid  ducting  is  used 

where  possible  instead  of  flexible  ducting,  this  will  ensure 

maximum performance.  

Before  carrying  out  the  installation  see  pages  11&12  for 

best practise recommendations.  

Important 

Precautions must be taken to avoid the back-flow of gases into 

the room from the open flue of gas or other fuel-burning appli-

ances. 

To remove front cover assembly, first make sure 

the  fan  is  off, 

isolated from the power supply 

and the 

iris shutter is fully 

closed

.  

1. Undo  the  locking  screw  at  the  bottom  edge  of  the  cover 

using a screwdriver.  

2. Rotate  the  cover  a  few  degrees  anticlockwise  until  it  clicks 

out from the fittings.  

3. Remove the cover by pulling it out.  

To refit the cover, reverse the above procedure. If when refit-

ting the front cover the iris stays open, remove the cover and 

don’t  attempt  to  refit  it  for  approx.  two  minutes  (allowing  the 

actuator to retract back in the closed position). Then try again.  

80000439 Issue 1 06/18 

Model 

iCON 30 (R) 

225 

144 

101 

97 

43 

51 

20 

30 

148 

iCON 30 (S) 

225 

144 

92 

97 

29 

Model 

iCON 15S 

197 

108.5 

67.5 

100 

40 

Page 3 of 16 

Range overview 

Part no. 

Model 

Air flow 

[l/s / m

3

/h] 

Power 

[W] 

Current 

[A] 

Noise level 

[dB(A) @ 3m] 

72683701 

iCON 15S 

21 / 77 

6.1 

0.07 

32.4 

72683801 

iCON 30S 

37 / 132 

12.2 

0.10 

36.2 

Page 4 of 16 

Electrical installation 

Electrical installation 

Page 5 of 16 

Page 6 of 16 

Mechanical installation 

Module clip 

Cable entry 

Cable clamp 

Module 

locating block 

Module fitting 

place 

Front cover removal 

iCON 15S 

iCON 30S 

Page 7 of 16 

Page 8 of 16 

Fitting on the wall 

iCON 15 

iCON 30 (R) 

Terminal  

connector 