INSTALLATION

 

 
 

 

 

 

 

 

www.airfieldaudio.com

 

- 3 -

 
 

    

5

              

1            2                          6                            4              3          

   

 

REAR PANEL VIEW 

 

 
 

1.

 

IMPORTANT 

:

  SET THE MAINS SWITCH ON THE REAR PANEL TO THE 

CORRECT VOLTAGE.  

 

2.

 

Be certain that the unit has a ½ AMP fuse (115 VAC mains)  
or ¼ AMP fuse (230 VAC mains). 

 

3.

 

Connect a line level audio input cable from your source (microphone preamp, EQ, 
guitar or bass preamp / effects box, analog console or analog output from your 
DAW) to the 3 pin XLR / ¼” female connector. The input connector is Balanced 
Transformer Coupled, pin 2 hot. 

 

4.

 

Connect an audio output cable to the 3 pin XLR male connector and plug it into 
the input of your recording or mixing device. The output XLR is Balanced 
Transformer Coupled, pin 2 hot. 

 

5.

 

Connect the supplied IEC power cable to the IEC mains socket on the rear panel. 
USE ONLY A 3 PRONG GROUNDED POWER CABLE. For safety reasons do 
not lift the ground on the power plug by using a 3 to 2 ground lift adapter. 

 

6.

 

Link Jack: connect a standard ¼” unbalanced guitar type cable between 2 
Liminator units for stereo operation. Y-cables should be used in a daisy-chain 
configuration for multi-channel operation of 3 or more Liminator channels.  

 

7.

 

Turn on the unit and allow 30 minutes warm up. 

Summary of Contents for LIMINATOR

Page 1: ...LIMINATOR CLASS A DUAL TRANSFORMER COMPRESSOR OWNER S MANUAL www airfieldaudio com ...

Page 2: ...TABLE OF CONTENTS SECTION PAGE INTRODUCTION 2 INSTALLATION 3 FRONT PANEL CONTROLS 4 OPERATION 5 SPECIFICATIONS 7 WARRANTY AND REGISTRATION 8 www airfieldaudio com 1 ...

Page 3: ...r is the inclusion of 2 switchable input transformers for a great range of flexibility and tone All front panel controls as well as internal components have been selected for ruggedness and long life We take pride in quality construction all units are handcrafted with care thoroughly bench tested calibrated and burned in for 48 hours The Airfield Audio Liminator exemplifies state of the art analog...

Page 4: ...ot 4 Connect an audio output cable to the 3 pin XLR male connector and plug it into the input of your recording or mixing device The output XLR is Balanced Transformer Coupled pin 2 hot 5 Connect the supplied IEC power cable to the IEC mains socket on the rear panel USE ONLY A 3 PRONG GROUNDED POWER CABLE For safety reasons do not lift the ground on the power plug by using a 3 to 2 ground lift ada...

Page 5: ...me compression E OUTPUT Continuously variable adjustment This control determines the amount of gain make up Fully ccw audio is off Fully cw gain is at maximum This control knob goes to 11 F METER Measures in decibels amount of gain reduction input level or output level according to meter switch G METER 3 position rotary switch select meter function In Input Level SWITCH GR Gain Reduction Out Outpu...

Page 6: ...tion of signal on the VU meter Normal gain reduction is 2 to 6dB Higher RATIO settings will result in deeper compression 8 While listening adjust the OUTPUT control to maintain an appropriate level back into your signal path To view the output level on the VU meter set METER switch to Out After In and Out levels have been checked it is recommended that the METER switch be normally left in GR posit...

Page 7: ...accurate flat response perfect for mixing mastering and pristine tracking T2 is a lower impedance Sowter transformer select it when thicker musical harmonics and richer tone are desired for tracking or mixing When using a pair of Liminator compressors linked for stereo operation both channels should be set to same input transformer 13 MODE Select Comp compress for normal unit operation or Bypass t...

Page 8: ...Hz 92 dB typical below operating level DISTORTION less than 02 THD at unity gain 4 dBu input level 1 THD at 24 dBu input level MAXIMUM OUTPUT 32 dBu into 600Ω GAIN REDUCTION RANGE 0 20 dB ATTACK 5 30 60 100 150 milliseconds RELEASE 1 3 6 2 6 seconds GAIN REDUCTION ELEMENT LD1 forward biased optical resistive module METER dB Gain Reduction dB Input dB Output 0VU 4dBu POWER REQUIREMENTS 15 watts 115...

Page 9: ... labor All returns to Airfield Audio require a return authorization number and must be in original packaging shipped to Airfield Audio via insured freight at the owner s expense Charges for transportation costs and damage in transit are not covered by this warranty The equipment will then be returned via prepaid insured freight method and carrier to be determined solely by Airfield Audio Airfield ...

Reviews: