Mounting

Figure 1

Make sure electrical power is shut off.

The ceiling outlet box MUST be metal and 
anchored securely enough to support a 
minimum of 80 lbs.

Loosen the 2 fixture mounting screws as 
shown in Figure 1.

Slide mounting plate onto the ceiling outlet 
box and secure by tightening the 2 fixture 
mounting screws. 

Check to make sure that the mounting plate 
is level. If it is not level use washers (not 
provided) secured with mounting screws 
between ceiling outlet box and mounting 
plate. Failure to level the mounting plate will 
cause your installed fan to wobble, creating 
noise and strain on the fan, and reducing the 
motor life.

Once mounting plate is properly installed, 
direct the electrical wires down so they are 
accessible.

Figure 2

Lift fan body (without blades) up to mounting 
plate and hook the metal safety cable securely 
over the hook on the mounting plate as shown 
in Figure 2.

Connect the electrical wires. All electrical 
connections should be done by a certified 
electrician.

Figure 1

Figure 2

Metal ceiling

outlet box
Mounting

plate

Safety cable

Hook

Ground and 

ground wire

Electrical 

connections 

secured with 

plastic wire 

connectors by 

certified 

electrician

Fixture 

mounting 

screws

Electrical Hookup

The installation shall be in accordance with the 

National Electrical Code, ANSI/NFPA 70 - 1999 and local codes. 

Disconnect power at main service panel. 

Lock in open position and tag it to prevent unexpected power application.

Check that power source conforms to electrical requirements of fan.

All electrical hookups should be made by a qualified person. 

Summary of Contents for CF60E

Page 1: ... done by qualified persons only in accordance with all applicable codes and standards WARNING Unplug or disconnect the fan before servicing WARNING Use this fan only in the manner intended by the manufacturer This fan is intended for permanent installation and to be used for air circulation only WARNING The secondary support cable included with the fan must be properly connected WARNING The fan sh...

Page 2: ... the electrical wires down so they are accessible Figure 2 Lift fan body without blades up to mounting plate and hook the metal safety cable securely over the hook on the mounting plate as shown in Figure 2 Connect the electrical wires All electrical connections should be done by a certified electrician Figure 1 Figure 2 Metal ceiling outlet box Mounting plate Safety cable Hook Ground and ground w...

Page 3: ...washers in their original holes as shown in figure 4 Tighten into motor housing Do not over tighten Attaching Blades Figure 4 Figure 3 Figure 3 Once all electrical work has been done position the wiring back up into the ceiling outlet box Lift and set the hanger ball into the mounting plate socket by aligning the groove in the hanger ball with the tab on the mounting plate socket as shown in Figur...

Page 4: ... Controls According to IEC60335 1 2006 Reversing Fan Direction Switch Bell Screw Figure 5 Remove screw from bell Slide bell up to reveal switch Slide switch to change motor direction Slide bell back down Align screw hole in bell with hole in down rod and reinstall screw Figure 5 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilitie...

Reviews: