Page 5 of 7
Revised 13/7/05
TESTING THE UNIT: See the instructions included with the REMOTE CONTROL.
1: Turn on power to the GPO.
2: Ensure new batteries are installed in the REMOTE CONTROL.
3: Press button 1. The RED LED lights up.
4: Choose MODE. Eg COOLING by cycling through button 5.
5: If cooling chosen set temperature (button 2) at least a few degrees cooler than ambient. The
GREEN LIGHT will illuminate when compressor starts. NB. Usually there will be a 3 minute delay .
6:CHECK THE FOLLOWING:
The outside discharge door has opened 90 degrees. There is no rattles or abnormal noises and the unit
is cooling.
7: Turn unit off and check the outside door closes fully.
NB. If the power is turned off at the GPO or the power to the van is disconnected before the unit is
properly turned off then the discharge door will not close.
RESETTING OF CONDENSER DISCHARGE DOOR:
If the door does not fully close when unit is turned off then proceed as follows: With unit turned off,
gently push the door shut. Turn unit on "fan only" and watch the door open. Turn unit off again and
door should close fully.
ONGOING MAINTENANCE
Normally the only item requiring ongoing attention is the return air filter. Aircommand recommends
that the filter is inspected at least monthly and depending upon how dusty the environment, the return
air filter may need to be removed, cleaned and replaced. To do this, grasp the filter with the finger
grip, pull outward and upward to remove the filter assembly (see fig. 10). Wash the filter in warm
soapy water and drain. Pick off any lint that did not wash away. To reinstall, carefully insert the filter
into the guides on either side, keep the filter square and push down gently until it is fully home.
More information https://www.caravansplus.com.au