Aircommand Cormorant MKII Installation & Operating Instructions Manual Download Page 13

 
 
 
 
 

GENERAL SPECIFICATIONS 

 
 
Air – Conditioner 

 
Height    

325mm 

Width    

675mm 

Length   

975mm 

Weight   

45kg 

 
Air Discharge Plenum 

 
Height   

65mm 

Width   

535mm 

Length   

555mm 

Weight   

2.4kg 

 
 
 

 

CORMORANT MODEL: 

 
 
 
Electrical Rating: 
 
Nominal Cooling Capacity: 
 
Nominal Heating Capacity: 
 
F.L.A. Cooling: 
 
F.L.A. Heating: 
 
Locked Rotor Amps: 
 
Refrigerant: 
 
Charge: 
 
Inside Air Delivery Maximum: 
 
Total Installed Weight: 

240V 50Hz Heatpump 

 
 
 
240V, 50Hz 
 
3.5 KW 
 
3.5 KW 
 
5.6 A 
 
5.2 A 
 
32 A 
 
R410A 
 
630 grams 
 
140 l/s 
 
48 Kg 

115V 60Hz Cooling Only 
Model 13500 

 
 
115V, 60Hz 
 
13,500 BTU/Hr 
 
n/a 
 
12.5 A 
 
n/a 
 
44 A 
 
R410A 
 
22 Oz 
 
 
 
106 lb 

115V 60Hz Heat Pump 
Model 15000

 

 
 
115V, 60Hz 
 
15,000 BTU/Hr 
 
15,000 BTU/Hr 
 
13.0 A 
 
13.0 A 
 
45 A 
 
R410A 
 
22 Oz 
 
 
 
108 lb 
 
 
 
 

 

Summary of Contents for Cormorant MKII

Page 1: ...OWNERS MANUAL INSTALLATION COMMISSIONING OF UNIT SPECIFICATIONS OPERATING INSTRUCTIONS...

Page 2: ...l GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifier gratuitement par notre agent de service tout d faut r sultant d un d faut de fab...

Page 3: ...NG INSTRUCTIONS FOR CORMORANT MKII ROOFTOP AIRCONDITIONER Model Number Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before install...

Page 4: ...V is parked in a shaded position In periods of extreme high temperature it is recommended to start the air conditioner earlier in the morning to greatly improve its ability to cope with the expected h...

Page 5: ...Installation must conform nationally to wiring regulations and in particular AS3001 2008 DO NOT attempt to modify or add components to the installation procedure This equipment must only be serviced b...

Page 6: ...ng could interfere with the discharge air flow from the plenum It is important that the unit is never more than 5 from the horizontal and the rear of the unit should never be higher than the front Con...

Page 7: ...nected at the supply mains and or battery Failure to do so may result in personal injury or death TIP Always use crawl boards across the roof to avoid damage Fig 3 Shows an ideal roof structure with s...

Page 8: ...w from under the roof Position the CORMORANT so the 4 mounting holes circled line up with the corners 5 ATTACH SPIGOT TO UNIT Screw spigot onto underside of unit with the 4 screws provided this step c...

Page 9: ...SEMBLE DUCT Thread a hold down bar onto the M8 bolt and push the bolt almost all the way into the hole in each corner of the brace Fig 9 Leave a 10mm gap between the hold down bar and the recess in th...

Page 10: ...d the spigot underneath the unit Fig 12 Then engage the four M8 bolts taking care to ensure the hold down bars slot into their recesses 10 ATTACH PLENUM COVER Connect the main cover of the plenum to t...

Page 11: ...a very small pilot hole may need to be drilled to guide the screws into place Replace the return air filters by sliding them into the plenum until they click into place Your installation is now comple...

Page 12: ...elderly Ensure that filters are cleaned in a safe and well ventilated area If a more thorough clean is required then the filters can be washed out using warm soapy water Care must be taken to avoid ri...

Page 13: ...eating Capacity F L A Cooling F L A Heating Locked Rotor Amps Refrigerant Charge Inside Air Delivery Maximum Total Installed Weight 240V 50Hz Heatpump 240V 50Hz 3 5 KW 3 5 KW 5 6 A 5 2 A 32 A R410A 63...

Page 14: ...will not re energize until the heat exchanger has warmed and then the fan will start to blow warm air DRY The DRY mode is used when the room temperature is close to comfortable but you wish to dehumid...

Page 15: ...must be below room temperature NB The compressor has a 3 minute delay before starting Ensure mode has be switched to heat check green LED Thermostat set point must be above room temperature NB The co...

Reviews: