Aircommand 8100001 Operating Instructions Manual Download Page 8

Ibis 3 Owners Guide  

 Revision V1 

Page 

8

 of 

19

 

2.  Attach weather collar to roof 

 

Locate the weather collar (Item #1). 

 

 

The collar has one side marked “THIS SIDE 
UP

”. This 

top side

 will point to the sky. Figure 

3

 

 

Figure 3 - Top side of weather collar showing THIS SIDE 

UP also has 4 grey foam strips around each bolt hole 

 

The other side, 

the underside 

will be sealed 

onto the roof. Figure 4

 

 

Figure 4 - The underside of the weather collar

 

Select a suitable sealant for bonding the 
weather collar to the caravan roof. The 
collar is made from glass filled Nylon-6,6. 

Consult your specialist adhesive supplier about 
the correct sealant to use for your application. 
Follow all directions on the MSDS particularly 
those regarding PPE, safe use & disposal. 

 

Apply the recommended sealant to the 

underside

  

of the weather collar 

Figure 5

 

Figure 5  - Recommended sealant path

 

 

 

Flip  the  collar  over  and  firmly  press  the  sealant 
side to the roof of the caravan. 

 

Apply a circle of sealant around each of the four 

bolt holes. 

Figure 6

 

 

Figure 6 - Sealant around bolt holes on the top side

 

 

 

The weather collar is now ready for the roof top 
unit. 

 

3.  Position roof top unit 

Use app 

roved methods to lift the unit 

– 46kg. 

 

Position the unit over the 360 x 360mm hole with 

the weather collar installed.

Figure 7

 

 

Lower the unit so that it engages with the collar.

 

 

 

Figure 7

– Lower & engage unit

 

 

 

Move inside the caravan.  

 

Note position of the electrical power supply 
entering the 360 x 360 hole. If the roof is thin (25-
30mm) you may have to put a notch in the duct & 
brace part in order to lead the cable through. 
 
 

 

 

Summary of Contents for 8100001

Page 1: ...________________________________________7 COMMISSIONING OF THE UNIT _________________________________________________________________11 MAINTENANCE_____________________________________________________...

Page 2: ...olgenden Adresse registriert werden www aircommand com au registration html GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifier gratui...

Page 3: ...OR IBIS 3 AIRCONDITIONER Model Number 8100001 Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before installation The unit must be in...

Page 4: ...from direct solar radiation Turning off unneeded appliances that might increase the heat load inside the van Cook outside if possible Park the caravan RV in a shaded position In periods of extreme hig...

Page 5: ...tation of the This Way UP arrows on the carton If the unit has been upside down for any period of time then DO NOT install Contact Aircommand Australia for advice Plenum Carton 557 x 577 x 119mm Weigh...

Page 6: ...n inverter power supply has been isolated Selected the correct sealant for your application Safe work method for lifting unit onto the roof top has been assessed Installation must conform to local wir...

Page 7: ...nit and any obstructions Figure 1 Figure 1 Foot print of the roof top air conditioner over 360 x 360mm mounting hole The area at the back shown in cross hatch must be kept free of obstructions INTERNA...

Page 8: ...SDS particularly those regarding PPE safe use disposal Apply the recommended sealant to the underside of the weather collar Figure 5 Figure 5 Recommended sealant path Flip the collar over and firmly p...

Page 9: ...installed unit Insert the M8 Bolt assembly through the corner holes Figure 9 Engage the bolts into the unit Ensure that the hold down bars are aligned with their recess Tighten the 4 bolts evenly Tigh...

Page 10: ...of the plenum will require additional fixtures Figure 13 IF REQUIRED Remove the cover caps Screw in countersunk wood screws provided Tighten until gap is gone Replace cover caps Figure 13 Extra screw...

Page 11: ...nge fan speed Press MODE button until COOL is selected Figure 20 Figure 20 Select COOL mode Decrease the set point temperature below the room temperature by pressing the TEMPERATURE DOWN button Figure...

Page 12: ...use higher concentrations of airborne particles and various other factors may result in the filters needing to be cleaned more often Replacement return air filters can be ordered directly from Aircom...

Page 13: ...AUSTRALIA PTY LTD IBIS 3 MODEL NO 8100001 230V AC 50Hz REFRIGERANT 407C 870 G RATED CAPACITY COOLING 3100 W HEATING 2700 W POWER INPUT COOLING 1300 W HEATING 1210 W RATED CURRENT COOLING 5 8 A HEATIN...

Page 14: ...s unit from standby to ON and vice versa 11 12 Temperature up down Increase or decrease the desired temperature set point for your comfort Also acts to increase decrease time during timer clock settin...

Page 15: ...10 until the required speed is selected Figure 19 Press TEMPERATURE UP DOWN for your required set point temperature Figure 21 DRY MODE Turn unit ON Press MODE until DRY is displayed in the Mode Displ...

Page 16: ...Ibis 3 Owners Guide Revision V1 Page 16 of 19 IBIS 3 COMPONENTS SPARE PARTS...

Page 17: ...8101014 1 18 Hold down plate piping 8101015 1 19 Electrical box RHS 8101016 3 20 Electrical box lid RHS 8101017 1 21 Electrical box LHS 8101018 1 22 Electrical box lid LHS 8101019 1 23 Control card 5...

Page 18: ...Ibis 3 Owners Guide Revision V1 Page 18 of 19 IBIS 3 WIRING DIAGRAM...

Page 19: ...bris has not blocked the external air intake of the roof top unit Clear intake grille High outside air temperatures in cooling Take action to reduce your peak heat load extend awnings close blinds win...

Reviews: