1. Problem:
The regulated pressure continues to increase after lock up without a change in control knob position.
Possible cause: Valve seat needs replacement

2. Problem:
Leakage through or around edge of bonnet
Possible cause:

1. Torque on bonnet is insufficient. Retorque bonnet.
2. Inspect for nicks and scratches on piston / diaphragm

Replace diaphragm and/or piston (repairkit)

5.3 Spare Parts
Only original spare parts must be used for repair or overhaul. Replacement only by trained personnel!
You find the repairkits under 

www.aircom.net

5.4 Repairs
Faulty / damaged units can be send back to AirCom Pneumatic GmbH. After checking the unit we will send you a
cost estimate with a first diagnostic. Regulators wich were not in use with air or neutral gases have to be cleaned
before you send them back for repair. Furthermore please note the used medium and a short error discription on the
delivery note.

Dok-Nr.: BA-R102

Page 4 of 4

Created on 2022-06-20

Summary of Contents for R102

Page 1: ...y instructions before performing installation operation and maintenance of fittings They enable to avoid dangers to people and units Handling of technical gases especially flammable or toxic gases requires knowledge of the subject observation of instructions for use and special safety measures In addition regulations and rules must be followed as applicable see 3 2 Use these units only as intended...

Page 2: ... check directly after delivery the pressure reducer for any transport damages and deficiencies The port openings of the pressure reducer are often closed via hole plugs to prevent contamination with dirty particles Remove plugs just before the assembly In case of further disassembly close the port openings again before storing or transporting Temporarily it can be done using a strip of adhesive ta...

Page 3: ... destroy the sealings Warning By placing and locking the handknob at a corresponding position on the adjusting screw or by placing and locking the adjusting screw at a corresponding position against the bonnet the maximum output pressure of some regulator types can be increased to a value considerably higher than the maximum output pressure signed on the unit Using a regulator with a output pressu...

Page 4: ...atches on piston diaphragm Replace diaphragm and or piston repairkit 5 3 Spare Parts Only original spare parts must be used for repair or overhaul Replacement only by trained personnel You find the repairkits under www aircom net 5 4 Repairs Faulty damaged units can be send back to AirCom Pneumatic GmbH After checking the unit we will send you a cost estimate with a first diagnostic Regulators wic...

Reviews: