background image

 

© Copyright AirBench Ltd 2016 

 

Page 4 of 20 

INTRODUCTION 

Overview 

Thank you for choosing VertEx as your fume or dust control system. Please read this document before 
installation and use. 

This document details maintenance activities which are essential to the safe use of your VertEx. We 
recommend that the Responsible Person reads this manual fully prior to installation and operation of the VertEx. 

This document refers to the VertEx range. Models of this type are available with a range of filter configurations. 
The filter configuration in use is detailed on the system Commissioning Certificate and is used within this 
document to provide filter-specific maintenance information. 

 

About VertEx 

VertEx is a self-contained cross draught extraction system which utilises a fan and filter combination selected 
for your specific application, to extract and filter dust/fumes and return filtered air to the work place. 

Some models vary in filtration and filtered air delivery point. 

It is used by running the fan at either fixed speed or variable speed (if speed controller fitted) to draw the 
pollutant away and through the filters, allowing work or the process to proceed next to the face. 

 

About this Document 

This document provides general maintenance and operation instructions for the VertEx range. It should be read 
in conjunction with the Commissioning Certificate supplied with the unit. If you have any concerns or doubts 
about maintenance or operation of this unit, contact the manufacturer. 

 

 

Summary of Contents for VertEx VA

Page 1: ...Copyright AirBench Ltd 2016 Page 1 of 20 VertEx VA Operation and Maintenance This Edition 19 November 2019 AirBench Ltd 6b Commerce Way Colchester CO2 8HR www airbench com 44 0 1206 791191 AIRBENCH LT...

Page 2: ...ACCESSORIES 6 Commissioning 7 GENERAL 7 IN HOUSE COMMISSIONING 7 Operation 8 PRIOR TO USE 8 GENERAL USE 8 Maintenance 10 FILTER CARE 10 SPARES 13 OTHER ROUTINE MAINTENANCE 15 Accessories 16 FILTER PR...

Page 3: ...mmissioning certificate The filters are not self cleaning They must be maintained cleaned replaced as described within Do not mix incompatible materials e g steel and aluminium It is the users respons...

Page 4: ...er specific maintenance information About VertEx VertEx is a self contained cross draught extraction system which utilises a fan and filter combination selected for your specific application to extrac...

Page 5: ...mplete VertEx unit If using a forklift to position the top section on the base section always ensure operators are fully trained and that other users are outside the working zone of the forklift Once...

Page 6: ...here via ductwork a discharge spigot will be visible These units are designed to connect to ductwork of the same size as the discharge spigot generally 250 or 300 mm diameter Ducting should be install...

Page 7: ...Ensure all operators are aware of the filter maintenance routine required for this machine Once complete you should note this on the commissioning certificate and retain the certificate for future re...

Page 8: ...full power Check the filter pressure gauge on the front of the unit If the needle on the gauge is showing in the upper red zone check the filter condition they may require cleaning or replacement This...

Page 9: ...Copyright AirBench Ltd 2016 Page 9 of 20...

Page 10: ...n the accompanying log sheet Take precautions and wear appropriate PPE when handing filters They may contain hazardous dusts i If using a vacuum cleaner to empty filters excessive cleaning will reduce...

Page 11: ...Copyright AirBench Ltd 2016 Page 11 of 20 Doors can be heavy Wear appropriate hand and foot protection...

Page 12: ...side or damaged MINIPLEAT FILTERS Mini pleat filters have fine paper pleats often around 5mm between pleats in a metal case This filter is not cleanable Replace the filter when it is stained on the c...

Page 13: ...MEDIA PADS Media pads are green and white fibreglass pads held in a metal frame These filters are not cleanable When replacing the frame and clip which hold the pad can be reused Always replace with w...

Page 14: ...Copyright AirBench Ltd 2016 Page 14 of 20...

Page 15: ...tasks suggests additional issues contact the manufacturer for advice FILTER SEALS These sit behind the filters and prevent dust passing into the body of the bench and the exhaust airstream It is impor...

Page 16: ...d operates at all times when the speed control or switch is powered Wheels Standard industrial rubber wheeled swivel castors are used The two front wheels are lockable Lock by pressing on the lever an...

Page 17: ...bed maintenance routines are being completed and recorded within the system logbook Condition check of fan filters electrics Performance testing according to recommended face velocities Visual check t...

Page 18: ...Copyright AirBench Ltd 2016 Page 18 of 20 TECHNICAL Arrangement...

Page 19: ...0 700 600 175 0 48 2 4 VA121218 1270 1800 700 1200 270 0 74 3 9 VA180618 1870 1800 700 600 225 0 74 3 9 VA120624 1270 2400 700 600 190 0 48 2 4 VA121224 1270 2400 700 1200 285 0 74 3 9 VA180624 1870 2...

Page 20: ...chinery Directive 2006 42 EC Low voltage Directive 2014 35 EU EN 60204 1 2018 Safety of machinery electrical equipment of machines general requirements EN 60335 2 80 Safety requirements for electric f...