6
8.
Fix chimney to the Murano Evo and wall (Fig
10).
Fig 10
9.
If you are using the back outlet then you must
turn the motor 90 degrees and fit the plate to
the top outlet (Fig 11).
Fig 11
3.2 Electrical Wiring
The electrical wiring must be performed by a
specialised electrician fully respecting current
standards and legislation in force. Check that the
power supply corresponds to the voltage requested
by the hood, which is given on the silver label stuck
inside the hood. Ensure that the wiring system
conforms to current standards and the earth
discharge works efficiently. Pay special attention to
the hood power cable, ensure that it does not pass
through any holes without a cable clamp. For direct
connection to the electrical mains it is necessary to
provide a device that ensures disconnection from the
electrical mains, with an opening distance of the
contacts that allows the complete disconnection
under the conditions of overvoltage category III, in
accordance with the rules of installation. The plug or
Omni polar switch must be accessible when the unit is
installed.
If the power cord is damaged, it must be replaced by
a special cord or assembly available from the
manufacturer or its service agent. The cable must be
of type H05VV-F 3 x 0.75mm
2
minimum cross-section.
The manufacturer declines all responsibility if the
current accident prevention standards in force are
not respected, which are needed for the wiring
system to operate correctly.