4

1)  Place fan in a clean, fresh air environment.

2)  Air quality of the confined space should be tested prior to ventilation.  If air quality of the confined space is  

      unacceptable, consult a trained professional.

3)  Inspect fan for damaged or worn parts, and inspect ducting for air leaks prior to fan operation.

4)  Install duct cuff to exhaust flange and secure. Keep bends and kinks in ducting to a minimum to maximimize 

      air flow. If canister model is used, secure canister with connect straps, open lid and pull out ducting. Inspect 

      for air leaks.

      

      

Note:

 Maximum recommended duct hose length is 25 ft.

5)  Set fan upwind from the work location and a minimum of 5 ft. from the manhole opening.

6)  Connect fan to power source.

      

      DC versions require 12 VDC. Attach the red connector to the positive (+) terminal and the black conector to 

      the negative (-) terminal. This unit must be run in the positive pressure mode as this model is not approved

      for extracting (sucking) air. DO NOT REVERSE WIRING.
      

WArNiNG: 

Vehicle electrical systems must be able to handle 15 amp service or electrical damage may occur.

      

      AC versions require 115 VAC/60Hz (SVF-8AC), 15 amp service or 220 VAC/50Hz (SVF-8AC50).

      

      

Note:

 If an extension cord is required, the minimum recommended size is 14 AWG up to 

                 25 ft. For further information refer to the National Electric Code Tables, Article 400.

 

7) Push ON/OFF switch to “I” position.

General Set-Up And operation

For SVF-8AC And SVF-8DC Models

MOTOR TYPE

1/3 HP, 115 VAC/60 Hz (SVF-8AC), 2.6 amps, or 220VAC/50 Hz (SVF-8AC50)

Capacitor Start, Single Speed, 3200 RPM, CSA Approved

OUTLET SIZE

8” Diameter (203mm)

FLOW RATES

Free Air: 1275 cfm (2166 cm/hr)

15 ft. duct with one 90° bend: 797 cfm (1354 cm/hr)

15 ft. duct with two 90° bends: 677 cfm (1150 cm/hr)

Specifications - AC Voltage Fans

MOTOR TYPE

1/6 HP, 13.5 VDC, 15 amps, Single Speed,  4200 RPM,

20 amp/32 VDC Slow Blow Fuse

OUTLET SIZE

8” Diameter (203mm)

FLOW RATES

Free Air: 1275 cfm (2166 cm/hr)

15 ft. duct with one 90° bend: 797 cfm (1354 cm/hr)

15 ft. duct with two 90° bends:  677 cfm (1150 cm/hr)

Specifications - DC Voltage Fans

Summary of Contents for SVF-15ACAN

Page 1: ...7 424 3967 Toll Free 1 800 866 8100 Fax No 757 424 5348 www airsystems com e mail sales airsystems com This manual must be read carefully and followed by all persons who have or will have the responsi...

Page 2: ...le Vent STEP 4 Install universal mount on Saddle Vent and set in place with manhole lid for support STEP 5 Install duct from blower to 90 elbow STEP 6 Turn on blower or fan Warning For explosive envir...

Page 3: ...al position or with the flange or guards removed Note If volatile or explosive vapors are suspected use Air Systems explosion proof electric blower Model No SVB E8EXP explosion proof in line fan Model...

Page 4: ...ved for extracting sucking air DO NOT REVERSE WIRING WARNING Vehicle electrical systems must be able to handle 15 amp service or electrical damage may occur AC versions require 115 VAC 60Hz SVF 8AC 15...

Page 5: ...DAXFAN2 6 ON OFF SWITCH ELSW038R 7 POWER CORD ELCB012 8 CAPACITOR MTR043CNC 9 RUBBER FOOT HDWR026 10A 8 DIA X 6 LONG DUCT SVF H6 10B 8 DIA X 15 LONG DUCT SVF H15 10C 8 DIA X 25 LONG DUCT SVF H25 11 DU...

Page 6: ...DAXFAN2 7 ON OFF SWITCH ELSW038R 8 POWER CORD ELCB045 9 RED BATTERY CLAMP ELA083R 10 BLACK BATTERY CLAMP ELA083B 11A BATTERY CONNECTOR FOR OPTIONAL BATTERY PACK P N BP 950 ELA127 11B 1 PAIR OF CONTACT...

Page 7: ...nd inspect for loose guards broken welds etc Circuit breaker trips SVF 8AC series only Voltage output insufficient Test outlet with volt meter Extension cord improperly sized Use 14 AWG extension cord...

Page 8: ...tS ANy otHer DireCt or iNDireCt CoStS eXPeNSeS loSSeS or DAMAGeS AriSiNG oUt oF DeFeCtS iN or FAilUre oF tHe ProDUCt or ANy PArt tHereoF The purchaser shall be solely responsible for compliance with a...

Reviews: