Air Specialties Softaire SA-90DC3 Manual Download Page 3

ASSEMBLY INSTRUCTIONS

2. Mount with mountion holes and hanger bar

5. INSTALL ROUND DUCTWORK

a. Slide one hanger bar into the channel on the housing and adjust as needed to fit between framing. 

b. Hold housing in place so that the housing contact the bottom of the joist, Screw housing to joist 

through the hole of the housing . 

c. Screw the hanger bar onto the other side of joist through the hole.

d. Screw hanger bar to housing with screw.   

e. Refer to the right diagram. 

a. Connect the round ductwork (not included) to the damper/duct connector, and run the ductwork 

to a roof or wall cap (not included). 

b. Using tape (not included), secure all the ductwork connections so that they are air tight.

c. Insulated flexible duct is recommended for the quietest possible installation. If rigid duct is used, 

a short (1-3 feet) section of insulated flexible duct will ensure quiet operation.

The ducting from this fan to the outside of building has a strong effect on the air flow, noise and 

energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and 

avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can 

reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve 

their rated air flow.

3. Mount to I-joist

4. Install DUCT AND BLOWER ASSEMBLY 

    

Hole

Hole

Hole

a. Slide one hanger bar into channel  on the housing and adjust as needed. 

b. Hold housing in place so that the housing contacts the bottom of the joist. 

c. Screw housing to joist through the hole of the housing.

d. Screw the hanger bar onto the  joist through the hole.

e. Screw hanger bar to housing with screw .

a.Install duct from the inside of the housing;Fix the duct by the tab.

b.Fix the BLOWER ASSEMBLY to the housing by 3 screws.

RETROFIT INSTALLATION

1. Remove wire panel and blower assembly before installation.

2. Fold mounting ears flat against housing.    

Blower

assembly

Wire

panel 

    

3. Enlarge ceiling opening to 9-1/2” by 9-1/2”, leave ductwork and wiring in place.

4. Connect wiring according to the wiring diagram.Re-install wire panel. 

5. Mounting fan    

a. Mount with additional mounting holes

    The interior of the fan housing contains additional mounting holes in case 

exterior mounting is not possible.

    

    Screw or nail the fan housing directly to the framing or joists. 

    Remove the blower assembly as directed in the service parts section of this 

manual to gain access to the additional mounting holes.

b. Mount with hole of the flange

    Use screws (included) to screw fans to the ceiling through the holes of the 

housing.

6. Connect duct

    Pull existing ducting through housing discharge opening and tape ducting to 

duct connector. Push connector/ducting back through opening,fix the duct by 

the tab.

7. Install the blower assembly.

additional mounting holes

Hole

Hole

Hole

Tab

9-1/2”

9-1/2”

3

Summary of Contents for Softaire SA-90DC3

Page 1: ...THIS PRODUCT IN A WALL 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Please read specification label on product for fu...

Page 2: ...USTMENT When the switch II is turned on the fan will run at high speed When the switch II is turned OFF fan will continue to run at the certified airflow rate until the delay timer 20 minutes has elap...

Page 3: ...AND BLOWER ASSEMBLY Hole Hole Hole a Slide one hanger bar into channel on the housing and adjust as needed b Hold housing in place so that the housing contacts the bottom of the joist c Screw housing...

Page 4: ...r Duct Connector 1 12 Power Box 1 Motor Plate Grille Spring Hanger Bars a 3 Screw b 3 Screw c 4 Screw d 2 Screw UNIT BLACK BLK SWITCH BOX SWITCH I POWER SUPPLY 120V AC GROUND GRD WHITE WHT FAN RECEPTA...

Page 5: ...r l appareil pour de plus amples informations et conditions Pour un fonctionnement silencieux et efficace une longue dur e de vie et une apparence attrayante abaisser ou retirer la grille et aspirer l...

Page 6: ...CAPTEUR D HUMIDIT Le ventilateur d tection d humidit utilise un capteur d humidit sophistiqu qui r pond a augmentation rapide de l humidit ou b l humidit au dessus du r glage par l utilisateur humidit...

Page 7: ...encieux Le conduit de ce ventilateur vers l ext rieur du b timent a un effet important sur le d bit d air le bruit et l utilisation d nergie du ventilateur Utilisez le chemin le plus court et le plus...

Page 8: ...vant de le remplacer NOIR BLK MISE TERRE GRD BLANC WHT R CEPTACLE DU VENTILATEUR PANNEAU DE CONNEXION BO TIER DE COMMUTATEUR UNIT BRUN BRN ALIMENTATION 120 VCA 1 2 3 4 5 6 c a b 8 7 9 11 12 10 d d Ass...