![Air Quality Engineering SMOKEMASTER C-12 Owner'S And Service Manual Download Page 13](http://html1.mh-extra.com/html/air-quality-engineering/smokemaster-c-12/smokemaster-c-12_owners-and-service-manual_2875459013.webp)
ARCING
From time to time, you may hear a snapping
noise coming from the electronic air cleaner.
This arcing occurs when the air cleaner collects
an unusually large particle or when the cells are
wet, extra-ordinarily dirty or damaged.
Check circuit fuse or breaker. Correct if fuse is
blown or breaker is tripped.
Be sure the electronic cells are in place, the
intake grille is closed and the unit is turned on.
If an unusual amount of arcing persists, check
first to determine if the electronic cells need
washing. Look also for any sign of bent collector
plates or broken ionizer wires.
If arcing still occurs when the cell is clean and
dry, consult your Air Quality Engineering, Inc.,
representative or dealer for repair.
PROBLEM 1
FAN OFF
LAMP OFF
1. Make sure the supply cord
is plugged into a standard
receptacle.
2. Make sure there is voltage
to the receptacle by using
any other electric device.
3. Make sure the top access
cover is properly in place in
order to actuate the interlock
switch.
PROBLEM 2
FAN ON
LAMP OFF
1. If the fan is on and the
light is out, the problem is
with the electronic cell or high
voltage power supply.
2. To determine which
component is
faulty…
- Remove the electronic cell,
and operate the air cleaner.
If the light does not come on,
then the high voltage power
supply will have to be
replaced.
3. If the indicator light does
come one, the problem is
with the electronic cell.
Check the cell for:
a. Bent collector plates.
Straighten and space the
plates using a needle
nose pliers.
b. Check for missing
ionizer wires. Replace
the missing wires.
c. Check for dirty buildup
on the collector plates
and the insulators. Wash
the cell thoroughly.
PROBLEM 3
FAN OFF
LAMP ON
1. Check the motor on all
three speeds. Be certain that
the control buttons are
pushed in all the way.
2. If the light is on and the
fan is off. The motor will
have to be replaced.
ELECTRICAL TROUBLESHOOTING
WARNING!
The following instructions are intended for
qualified service personnel only. Dangerous
line voltage circuits are exposed during this
procedure. Disconnect the power before
servicing the unit.
Page 13
S M O K E M A S T E R C - 1 2 O W N E R ' S M A N U A L
Pure n Natural Systems, Inc. | purennatural.com | 1-800-237-9199