background image

MR-200 SERIES 

MULTI-VOLTAGE RELAY INSTALLATION GUIDE

PRODUCT SPECIFICATIONS

POWER REQUIREMENTS:

AMBIENT TEMPERATURE:

CONTACT RATINGS:

CONTACT CONSTRUCTION:

MR-100 Series: Dry form “C” SPDT per module position

WIRING:

Solid or stranded: #12 to #22 AWG terminals

“/C” VERSIONS:

Backbox: 18ga CRS, plated with ½" conduit knockouts top and bottom

MR-104, MR-204: CRS 18ga (“/C” Grey, “/C/R” Red)   

APPROVALS:

32ºF to 120ºF (0ºC to 49ºC) @ 85% RH                Non-Condensing / Non-Freezing

“/T” VERSIONS:

3.5" wide, low profile snap track provided with mounting screws

MR-101, MR-201: plastic ABS 94V-0 (“/C” Grey, “/C/R” Red)

POLARIZED COIL INPUT(S):
ENERGIZED INDICATOR:

One red LED per module position

Cover Material:

 MR-100 Series: 24(18-35)VDC / 24(18-35)VAC / 120VAC / 230VAC @ 18mA per module position 

DC control inputs only

Resistive load: 7A @ 28VDC, 10A (NO: 1/6HP, NC: 1/8HP) @ 120VAC, 7A @ 230VAC 

 (@32ºC)

MR-100 SERIES 

MR-200 Series: Dry form “C” DPDT per module position

“T” versions: UL Recognized Component 

(UL864, UOXX2) 

File #S3403, CSFM File #7300-1004:106

UL Listed 

(UL864, UOXX)

, CUL Listed 

(UL864, UOXX7)

File #S3403, CSFM File #7300-1004:101, 

MEA File #73-92-E Vol.14 

(MR-101, MR-104),

Vol. 16 

(MR-201, MR-204)

“C” versions:

“C/R” versions: UL Listed 

(UL864, UOXX)

, CUL Listed 

(UL864, UOXX7)

File #S3403, 

CSFM File #7300-1004:101, MEA File #73-92-E Vol. 22

 MR-200 Series: 24(18-35)VDC / 24(18-35)VAC / 120VAC / 230VAC @ 40mA per module position

    © Air Products and Controls Inc. 2005   1749 East Highwood   Pontiac, MI  48340   Ph. (248) 332-3900   Fax (248) 332-8807   www.ap-c.com     INST AP-021 B050203

WIRING

LOAD POWER 

SOURCE

LOAD

-/N

+/AC

+/AC

-/N

CAUTION: 

DE-ENERGIZE ALL POWER BEFORE INSTALLATION OR SERVICE

!

24(18-35)VDC @ 18mA

120VAC @ 18mA

NC   C    NO

ON

MR-101

SPDT CONTACT

 7A @ 28VDC, 10A (NO: 1/6HP, NC: 1/8HP) 

@ 120VAC, 7A @ 230VAC 

RELAY 

ENERGIZED 

LED

INPUT 

CONTROL

VOLTAGES

FOR ADDITIONAL APPLICATION INFORMATION AND/OR ASSISTANCE, 

PLEASE CONTACT OUR TECHNICAL SUPPORT HOTLINE. (888) 332-2241

(TYPICAL FOR ONE 

MODULE POSITION)

0 18/24 115 230

L1

H

A.C.

A.C.

N

L2

(+)

(-)

24(18-35)VAC @ 18mA

 230VAC @ 18mA

24(18-35)VDC @ 40mA

120VAC @ 40mA

NC   C   NO

ON

MR-201

DPDT CONTACTS

 7A @ 28VDC, 10A (NO: 1/6HP, NC: 1/8HP) 

@ 120VAC, 7A @ 230VAC 

RELAY 

ENERGIZED 

LED

NC   C   NO

INPUT 

CONTROL

VOLTAGES

0 18/24 115

230

L1

H

A.C.

A.C.

N

L2

(+)

(-)

24(18-35)VAC @ 40mA

 230VAC @ 40mA

NOTE: 

230VAC NOT INTENDED FOR CONTINUOUS USE

RECOGNIZED COMPONENT

WHEN RELAY COIL ENERGIZES, 
“NC” CONTACTS ARE SWITCHED 
TO OPEN POSITION, REMOVING 
POWER TO TURN OFF LOAD

APPLICATION EXAMPLE

NC  C    NO

ON

0 18/24 115 230

RELAY POWER 

SUPPLY

-/N +/AC

MEA 

ACCEPTED

CSFM LISTED