Air Oasis Dual Induct (120v) Owner'S Manual Download Page 5

2

Step 4

Plug the power cord into an electrical outlet. You may optionally have an 

electrician wire the air purifier to your HVAC unit so that the air purifier only 

operates when your HVAC fan is running.  Once the unit is plugged in the 

indicator light should glow to indicate the AHPCO Cell is working properly.

5

AHPCO™ Cell Replacement

Step 1

CAUTION: Before attempting to service the Air Oasis unit, be sure the 

power is off and unplugged.

Remove three (3) screws at the top of 

the aluminum face plate.  Then slide 

the face plate up and off.

Step 2

Unplug  the  four  pin  lamp  connec

-

tors  and  fiber  optic  cords  from  the 

AHPCO   Cell.

Read all instructions carefully before operating 

your air purifier.