AHPCO® Cell (2018 - Present) 

Replacement  Instructions

3401 Airway Blvd.

Amarillo, Texas  79118

806-373-7788

[email protected]

®

1.  Remove  the  screws  on  the 

sides  of  the brushed  aluminum 

shell  then  remove  the shell 

from the base of the unit.

6. Slide shell down onto base 

and replace screws.  (Cord and 

switch are to the back.)

2. Use a  Phillips head 

screwdriver to remove the 

screws from the AHPCO

®

 Cell.

NOTE: Before you begin please unplug the unit from it's power source. 

 Phillips head screwdriver or drill with Phillips head bit.

Required Tools:

3. Grasp the AHPCO®  Cell and 

pull to the side, then remove 

the lamp connector.

            CAUTION

UV lamp may be hot and could cause 

serious burns if not handled properly.  

Please wait until AHPCO®  Cell has cooled 

to room temperature to remove from unit. 

5. Plug in the AHPCO® Cell, slide 

the reset switch. Your unit will 

beep in 2 years when it is time to 

replace the AHPCO® Cell.

4. Connect the lamp connector 

securely onto the AHPCO®  Cell 

and use a Phillips head screw-

driver to tighten the screws to 

secure the AHPCO® Cell.

WARNING

AHPCO® Cell contains Hg (Mercury) 

and should be disposed of according 

to disposal laws. Find disposal 

centers at www.earth911.org. 