LIMITED WARRANTY

All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or material. In addition, all ventilating/exhaust
fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and/or material.

This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as: range hood grease filters, charcoal
filters or combination charcoal/grease filters; replacement light bulbs in range hoods or bathroom fan/light/bulb heater combinations. As well, any damage or failure caused by
abuse, misuse, abnormal usage, faulty installation, or improper maintenance will not be covered by this warranty.

In order to make a claim on this warranty, you must be the original consumer of the product. You will be required to present to Air King the original bill of sale showing: date of
purchase, place of purchase and model purchased. Failure to meet these requirements will void your warranty.

Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and
provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these
exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

FOR PARTS OR TECHNICAL ASSISTANCE

Please call: 1-800-465-7300, 

MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST.PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE.

Reference the type and style of product (located on label inside of the product) when you call. For more information please visit our website: wwwairkinglimited.com

4 of 20

#

Qty. Description

Replacement Part #

22

1

Capacitor

5S6113094

23

1

Terminal Strip

5S6113095

24

1

Wire

5S6113096

25

2

Filter 

(SEV30 models Qty. 3)

5S6113028

26

2

Lamp Holder

5S6113097

27

1

Gasket

5S6113098

28

4

Mounting Screws

5S6113099

#

Qty. Description

Replacement Part #

1

1

Collar

5S6113014

2

1

Body - SEV24

5S6113017

1

Body - SEV30

5S6113020

3

2

Wire Clamp

5S6113012

4

1

Damper

5S6113082

5

2

Damper Springs

5S6113083

6

2

Washer

5S6113009

7

1

Wire Compartment

5S6113010

8

1

Wire Compartment Cover

5S6113011

9

1

Wire Compartment Barcket

5S6113012

10

1

Wire Clamp

5S6113013

11

1

Control Panel Plate

5S6113084

12

1

Control Panel Compartment

5S6113085

13

1

Motor Switch

5S6113086

14

1

Light Switch

5S6113087

15

1

Motor Grill

5S6113088

16

1

Shock Absorber

5S6113089

17

1

Motor Mounting Bracket

5S6113090

18

1

Motor

5S6113091

19

1

Fan Blade

5S6113071

20

1

Motor Housing

5S6113092

21

1

Motor Connection Box

5S6113093

1

2

3

5

4

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

Installer: _________________________________________________________

Installation Date:_________________________________________

Place of Purchase: _________________________________________________

Model Number: __________________________________________

Summary of Contents for SEVILLE SERIES

Page 1: ... OR EXPLOSIVE MATERIALS AND VAPORS 6 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS CRAWL SPACES OR GARAGES 7 This unit must be grounded 8 To avoid motor bearing damage and no...

Page 2: ...0000 Rev A 5 08 INSTALLATION INSTRUCTIONS CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION SECTION 1 Preparing the Range Hood 1 Unpack hood from the carton and confirm that all pieces are present In addition to the range hood you should have 1 Package containing 1 duct collar 4 3 mm x 11 mm mounting screws 4 4 mm x 15 mm mounting screws 24 models 2 Aluminum Gre...

Page 3: ...lace and release handle The filter should snap securely into place Figure 6 NOTE If your model is equipped with a filter screw slide tab at rear of filter into slot in hood and secure filters in place by tightening screw located at front of filter DO NOT OVERTIGHTEN 3 If the grease filters become damaged replace with the Air King Model BCGF 01 Grease Filters Cleaning CAUTION DO NOT USE GASOLINE BE...

Page 4: ...ons may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province FOR PARTS OR TECHNICAL ASSISTANCE Please call 1 800 465 7300 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 4 00 PM EST PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE Reference the type and style of product located on label inside of t...

Reviews: