Air King SEV24AB Important Instructions & Operating Manual Download Page 2

INSTALLATION INSTRUCTIONS

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Insert

1.  Unpack hood from the carton and confirm that all pieces are present. In addition to the 

range hood you should have:

 

 

1 -  Duct collar

 

 

1 -  Wire compartment

 

 

SEV24 models: 2 - Aluminum Grease Filters (shipped installed)

 

 

SEV28 and SEV30 models: 3 - Aluminum Grease Filters (shipped installed)

 

 

2 -  50 watt Halogen lamps

 

 

1 -  Instruction/Safety Sheet   

NOTE:

 Some hoods may be shipped with a protective plastic adhered to the underside of the 

unit. It is recommended to leave this in place during installation to protect it from scratching. 

Remove when the installation is complete.

SECTION 2

Preparing the Area

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION:

 WHEN CUTTING OR DRILLING INTO WALL DO NOT 

DAMAGE ELECTRICAL WIRING AND OTHER HIDDEN UTILITIES.

1.  Most building codes require noncombustible material above the cooking surface. If 

you you have wood or some other combustible material on the bottom of your cabinets 

it is recommended that you use the optional hood liner (See 

Section 3

) If you have 

noncombustible material cut an appropriate size hole into the cabinet or canopy the 

power unit will be mounted into 

(Figure 1):

 

 

SEV24 models: 18" wide by 10" deep.

 

 

SEV28 models: 26-7/8"" wide by 10" deep.

 

 

SEV30 models: 30" wide by 10" deep

NOTE:

 The hood must be mounted a minimum of 24” and a maximum of 36” from the 

cooking surface.

SECTION 3

Optional Hood Liner

CAUTION:

 MAKE SURE THE SURFACE YOU ARE MOUNTING THE 

INSERT AND LINER TO IS CAPABLE OF SUPPORTING THE WEIGHT OF THE UNIT. 

OTHERWISE YOU WILL NEED TO REINFORCE THE AREA.

1.  Secure the liner to the cabinet frame or custom canopy using three screws on each end 

of the liner and 3 screws on each side of the top of the liner 

(Figure 2).

www.airkinglimited.com

6728012 Rev. N 12-15

2 of 12

SECTION 4

Installing the Insert

2.  Insert the power unit into the hole and secure to liner using the screws provided with the 

Liner 

(Figure 3).

NOTE:

 If an optional Air King Liner is not being used; use appropriate hardware to install the 

unit in place, making sure to comply with all Local and National Building Codes.

CAUTION:

 MAKE SURE THE SURFACE YOU ARE MOUNTING THE 

POWER UNIT TO IS CAPABLE OF SUPPORTING THE WEIGHT OF THE UNIT. 

OTHERWISE YOU WILL NEED TO REINFORCE THE AREA.

SECTION 5

Ducting

CAUTION:

 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

WARNING:

 TO REDUCE THE RISK OF FIRE, USE ONLY 

METAL DUCTWORK.

1.  Install the included duct collar to the hood with two of the provided #6 blunt tip screws 

(Figure 4).

When there is access to the top of the unit, connect the ducting to the duct collar and 

secure in place using tape to seal all joints 

(Figure 4).

3.  When there is no access to the top of the hood, carefully pull down the metal duct through 

the custom hood base hole. Slide this duct over the duct collar. Make sure the adapter/

damper assembly enters the ducting. Seal the connection with duct tape.

NOTE:

 To achieve proper air flow, 6" round ducting is required. The duct connector is 5.8" in 

diameter (for 6" round ducting) and the center is located 3.1875" inches from the back wall.

CAUTION:

 ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A 

WALL OR ROOF CAP.

SECTION 6

Wiring

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE MADE 

IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL 

ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL 

WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

Examine the wire compartment cover and select the most convenient wire entrance 

and remove the knock out. Feed the supply wire through the opening and install an 

appropriate strain relief. Connect the white wire from the power unit to the white wire 

from the supply. Connect the black wire from the power unit to the black wire of the 

supply. Connect the ground wire from the home (green or bare) to the ground wire of the 

power unit (green or green/yellow). Use approved methods for all connections 

(Figure 5).

Figure 1

18" / 26-7/8" / 30"

10

"

Figure 2

Figure 3

Figure 4

Duct Collar

Ducting

Power Unit

Summary of Contents for SEV24AB

Page 1: ...noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit g Read all instructions before installing or using range hood WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOC...

Page 2: ...into the hole and secure to liner using the screws provided with the Liner Figure 3 NOTE If an optional Air King Liner is not being used use appropriate hardware to install the unit in place making s...

Page 3: ...SVGF 03 Grease Filters Changing the Lamp 1 To remove replace the light bulb remove the filters using the procedure listed above 2 Locate the lamp holder bracket mounted on the back wall of the hood Fi...

Page 4: ...WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an im...

Page 5: ...5S1137049 5 1 Blower Assembly 5S2137810 1 Blower Assembly AB models 5S1140018 6 1 Fan Switch 5S1144085 7 1 Light Switch 5S4199018 8 1 Switch Plate 5S1142010 9 2 Knob 5S1142011 10 2 Lamp Holder 5S11377...

Page 6: ...www airkinglimited com 6728012 Rev N 12 15 6 of 12 NOTES...

Page 7: ...c d atteindre l unit de puissance g Lire toutes les instructions avant d installer ou d utiliser la hotte de cuisine AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE OU DE CHOC LECTRIQUE NE PAS UTILI...

Page 8: ...sance dans le trou et fixez la au rev tement utilisant les vis fournies avec le rev tement Figure 3 REMARQUE Si un rev tement Air King facultatif n est pas utilis utilisez le mat riel appropri pour in...

Page 9: ...suivant le processus indiqu ci dessus 2 Trouvez le support de lampe mont sur le mur arri re de la hotte Figure 9 3 Desserrez les crous papillons sup rieurs inf rieurs de quelques tours en tournant da...

Page 10: ...ON DE LA P RIODE DE GARANTIE Certains tats et provinces ne permettent pas les limitations de la p riode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par cons q...

Page 11: ...lement de ventilateur 5S2137810 1 Assemblement de ventilateur mod les AB 5S1140018 6 1 Interrupteur du moteur 5S1144085 7 1 Interrupteur du lampe 5S4199018 8 1 Plaque d interrupteur 5S1142010 9 2 Bout...

Page 12: ...www airkinglimited com 6728012 Rev N 12 15 12 of 12 REMARQUE...