Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Fan does not operate. 

1a.  Control setting. 

1a.  Check temperature and humidity level settings. If the intake air is not within

     

 

 

 

the preset range, the fan will not turn on. Either adjust the settings or wait

     

 

 

 

for the intake air temperature and/or humidity to change.

     

1b.  A fuse may be blown or a circuit tripped. 

1b.  Replace fuse or reset circuit breaker.

     

1c.  Wiring is not connected properly. 

1c.  Turn off power to unit. Check that all wires are connected.

     

1d 

Motor has stopped operating. 

1d.  Replace motor.

  2.  Fan is operating, but air moves slower than normal. 

2a.  Obstruction in the ducting. 

2a.  Check for any obstructions in the ducting. The most common are bird

     

 

 

 

nests in the roof cap or wall cap where the fan intakes from the outside.

     

2b.  Filter is clogged 

2b.  Change air filter (if equipped).

     

 

 

2c.  Change/clear bug filter

  3.  Fan is operating louder than normal 

3a.  Motor is loose. 

3a.  Turn off power to unit and check that all screws are fully tightened

     

 

 

 

Restore power to unit.

     

3b.  Fan blade is hitting housing of unit. 

3b.  Call your dealer for service.

Summary of Contents for QuFresh QFAM

Page 1: ...tion b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the l...

Page 2: ...nergy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated air flow WARNING MAKE SURE THE FRESH AIR INTAKE PORT COMPLIES WITH ALL LOCAL AND NATIONAL CODES AND IS LOCATED AT LEAST 6 FEET AWAY FROM SOURCES OF CONTAMINATION SUCH AS BUT NOT LIMITED TO DRYER FURNACE OR CENTRAL VACUUM EXHAUSTS GAS APPLIANCES SUCH AS BBQ GRILLS GARBAGE BINS OR OTHER EXHAUST PORTS NO...

Page 3: ...s from entering into the living space 1 If you have not already pressed the ON button in step one of this section do so now Press the CONFIGURE button once and the display will show a C and Temp Unit on the right hand side 2 Press the up or down button to display the temperature in Fahrenheit or Celsius 3 Press the CONFIGURE button again to set the upper limit temperature This is the temperature t...

Page 4: ... replaced at least once every 3 months Reverse the instructions in the SECTION 7 of these instructions to remove filter NOTE If you notice a large amount of insects and debris in the air filter this could be a sign that the intake weather hood roof cap or wall cap might be compromised and need repair or replacing CALIFORNIA RESIDENTS ONLY WARNING THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL OR CHEMIC...

Page 5: ... is not connected properly 1c Turn off power to unit Check that all wires are connected 1d Motor has stopped operating 1d Replace motor 2 Fan is operating but air moves slower than normal 2a Obstruction in the ducting 2a Check for any obstructions in the ducting The most common are bird nests in the roof cap or wall cap where the fan intakes from the outside 2b Filter is clogged 2b Change air filt...

Page 6: ... KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMIN...

Page 7: ... 5S1650001 2 1 6 Metal Collar Intake 5S1650002 3 1 6 Metal Collar Outlet 5S1650003 4 1 Blower Assembly 5S2202013 5 1 Wire Compartment Assembly 5S1650100 6 3 Adjustment Knobs 5S1299802 7 1 LCD Controller 5S1650004 9 0 8 0 7 0 L o w e r 6 0 5 0 4 0 3 0 High Low 1 3 0 1 2 0 1 1 0 1 0 0 5 6 7 REPLACEMENT PARTS DIAGRAM ...

Page 8: ...www airkinglimited com 6728076 Rev G 5 17 8 of 8 NOTES ...

Reviews: