Air King LI34 Operating Manual Download Page 1

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions

should always be followed to reduce the risk of fire,

electric shock and injury to person, including the following:

SAVE THESE INSTRUCTIONS

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND 

INJURY TO PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer. If you 

have questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service panel 

and lock the service disconnecting means to prevent power from 

being switched on accidentally. When the service disconnecting means 

cannot be locked, securely fasten a prominent warning device, such as 

a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND 

INJURY TO PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA) and the American Society for Heating, 

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

WARNING:

 

TO REDUCE THE RISK OF FIRE AND TO PROPERLY 

EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT 

EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO 

ATTICS, CRAWL SPACES, OR GARAGES.

d)  Ducted fans must always be vented to the outdoors.
e)  This unit must be grounded.
f)  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power unit.

g)  Read all instructions before installing or using exhaust fan.

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO 

NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.

WARNING:

 TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

 

a)  Never leave surface units unattended at high settings. Boilovers 

cause smoking and greasy spillovers that may ignite. Heat oils 

slowly on low or medium settings.

 

b)  Always turn hood ON when cooking at high heat or when 

flambéing food (ie. Crepes Suzette, Cherries Jubilee, 

Peppercorn Beef Flambé).

 

c)  Clean ventilating fans frequently. Grease should not be allowed to 

accumulate on fan filter.

 

d)  Use proper pan size. Always use cookware appropriate for the size 

of the surface element.

WARNING:

 TO REDUCE THE RISK OF INJURY TO PERSONS IN 

THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

 

a)  SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal 

tray, then turn off burner. BE CAREFUL TO PREVENT BURNS. If the 

flames do not go out immediately, EVACUATE AND CALL THE FIRE 

DEPARTMENT.

 

b)  NEVER PICK UP A FLAMING PAN - You may be burned.

 

c)  DO NOT USE WATER, including wet dishcloths or towels - 

a violent steam explosion will result.

 

d)  Use an extinguisher ONLY if:

 

I. 

You know you have a Class ABC extinguisher, and you 

already know how to operate it.

 

II.  The fire is small and contained in the area where it started.

 

III.  The fire department is being called.

 

IV.  You can fight the fire with your back to an exit.

WARNING: 

TO REDUCE THE RISK OF FIRE, USE ONLY METAL 

DUCTWORK.

www.airkinglimited.com

6728024M Rev. D 9-12

1 of 12

Powered Liner

LIN Series

Summary of Contents for LI34

Page 1: ...do not damage electrical wiring and other hidden utilities WARNING TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS CRAWL SPACES OR GARAGES d Ducted fans must always be vented to the outdoors e This unit must be grounded f To avoid motor bearing damage and noisy and or unbalanced impellers...

Page 2: ...mited com 6728024M Rev D 9 12 2 of 12 NOTE If additional support is required install a 2 x 75 strip of wood between the back of the canopy rear wall and the hood When installing the wood strip to the back of the canopy locate studs in the wall to support the weight of the canopy Center the wood strip 11 5 from the bottom of the canopy and attach the strip to at least two studs in the rear wall do ...

Page 3: ...te Hot Black Figure 7 Outlet Adapter Hood Screws Flange Figure 5 Ducting 2 If the included removable grease trough is not already installed within the hood insert into the rear inside channel of the hood Make sure the taller side of the trough is facing towards the back of the hood Figure 8 3 Install the baffle filters and any spacers included with the unit by inserting the top of the filter into ...

Page 4: ...required before a warranty claim will be accepted CUSTOMER SERVICE Toll Free 800 465 7300 Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Monday through Friday 8am 4pm Eastern Please have your model number available as well as the type and style located on the label inside of your product Please do not r...

Page 5: ...ion Replacement Part 9 2 Lamp Holder 5S1136075 10 2 45w PAR16 Bulb 5S1136099 11 2 Baffle Filter PHGB2 5S1136078 12 1 Grease Tray 5S1141370 LIN28 MODELS Qty Description Replacement Part 9 2 Lamp Holder 5S1136075 10 2 45w PAR16 Bulb 5S1136099 11 2 Baffle Filter PHGB3 5S1136079 12 1 Grease Tray 5S1136135 LIN34 MODELS Qty Description Replacement Part 9 2 Lamp Holder 5S1136075 10 2 45w PAR16 Bulb 5S113...

Page 6: ...www airkinglimited com 6728024M Rev D 9 12 6 of 12 NOTES ...

Page 7: ...VACUER L AIR VERS L EXTÉRIEUR NE PAS ÉVACUER L AIR DANS DES ESPACES DANS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECHNIQUES OU LES GARAGES d Les ventilateurs avec conduits doivent toujours être évacués vers l extérieur e Cette unité doit être mise à la terre f Pour éviter des dommages aux roulements des moteurs et ou des hélices bruyantes ou déséquilibrées empêcher la poussière de clois...

Page 8: ...2 8 of 12 REMARQUE Si vous avez besoin d un support additionnel installez une bande en bois de 2 po X 75 po entre le dos de l armoire mur arrière et la hotte En installant la bande en bois sur le dos de l armoire localisez les goujons dans le mur pour soutenir le poids de l armoire Centrez la bande en bois à 11 5 po du fond de l armoire et attachez la bande à au moins deux goujons dans le mur arri...

Page 9: ...pes halogènes Utiliser des lampes PAR16 de base moyenne d un maximum de 45 watts L installer en insérant la lampe dans le réceptacle et en tournant en sens horaire jusqu à ce que la lampe soit fermement installée NE PAS serrer à outrance Connecteur à fils Figure 6 Vis Alimentation provenant de la maison Terre Vert ou nu Neutre blanc Vivant noir Figure 7 Adaptateur de sortie Hotte Vis Bride Figure ...

Page 10: ...iode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par conséquent les présentes restrictions ne peuvent pas s appliquer La présente garantie vous donne des droits légaux spécifiques et peut être certains autres droits qui peuvent varier selon la province La preuve d achat est exigée avant qu une réclamation de garantie ne soit acceptée SERVICE À LA CLIENTÈLE...

Page 11: ...N24 TOUS LES MODÈLES LIN de pièce Qté Description de remplacement 9 2 Douille 5S1136075 10 2 Lampe PAR16 de 45W 5S1136099 11 2 Filtre déflecteur PHGB2 5S1136078 12 1 Dalot à graisse 5S1141370 MODÈLES LIN28 de pièce Qté Description de remplacement 9 2 Douille 5S1136075 10 2 Lampe PAR16 de 45W 5S1136099 11 2 Filtre déflecteur PHGB3 5S1136079 12 1 Dalot à graisse 5S1136135 MODÈLES LIN34 de pièce Qté ...

Page 12: ...www airkinglimited com 6728024M Rev D 9 12 12 of 12 REMARQUES ...

Reviews: