Air King BFQF50 Operating Manual Download Page 5

www.airkinglimited.com

A210572219 Rev. D 12-12

5 of 12

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

LIMITED WARRANTY

WHAT THIS WARRANTY COVERS:

 This product is warranted against defects in workmanship and/or materials. 

HOW LONG THIS WARRANTY LASTS:

 This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase 

or until the original purchaser of the product sells or transfers the product, whichever first occurs. 

WHAT AIR KING WILL DO:

 During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole 

product with the same or comparable model. 

WHAT THIS WARRANTY DOES NOT COVER:

 This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, 

shipping damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or 

replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement 

ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR 

FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST 

OCCURS AND IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES 

FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO 

THE CONTRARY, IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT 

AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these 

exclusions or limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to 

province. Proof of purchase is required before a warranty claim will be accepted. 

CUSTOMER SERVICE:

Toll-Free (800) 465-7300

Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through 

Friday, 8am-4pm Eastern. Please have your model number available, as well as the type and style (located on the label inside of your product). 

Please do not return product to place of purchase.

www.airkinglimited.com

PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS 

AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.

Summary of Contents for BFQF50

Page 1: ...y qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Associati...

Page 2: ... bottom of the fan will be flush with the finished ceiling Nail or screw the bracket in place securely Figure 3 2 Snap the fan body into the bracket Figure 4 The fan can be snapped into position with the duct collar facing to the left or the right depending which is most convenient www airkinglimited com A210572219 Rev D 12 12 2 of 12 SECTION 3 Existing Construction 1 Position housing against the ...

Page 3: ...to both the black wire from the fan s light receptacle and the black wire from the fan s exhaust receptacle Connect the ground wire from the house to the green wire from the fan s receptacle Figure 8 Use approved methods for all connections www airkinglimited com A210572219 Rev D 12 12 3 of 12 SECTION 6 Completing the Installation 1 Reinstall the fan s wire compartment cover Rotate the blower whee...

Page 4: ...om receptacle Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Plug the motor cord back in and restore power Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1 Fan does not operate when the switch is on 1a A fuse may be blown or a circuit tripped 1a Replace fuse or reset circuit breaker 1b Connector plug from motor is not plugged in 1b T...

Page 5: ... THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURC...

Page 6: ... Clip 5S2205025 6 1 Wire Cover 5S2205040 7 1 Blower Wheel 5S2299004 8 1 Motor BFQF50 5S2299011 Motor BFQF70 5S2299012 9 1 Clip 5S2205029 10 1 Motor Bracket 5S2299003 11 1 Grill Assembly 5S9205030 12 1 Light Lens 5S2205031 13 1 26 Watt Lamp 5S9999010 www airkinglimited com A210572219 Rev D 12 12 6 of 12 REPLACEMENT PARTS DIAGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Page 7: ...es codes et normes applicables incluant la construction relative aux incendies b De l air en quantité suffisante est requis pour la bonne combustion et l évacuation de gaz par le conduit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la Na...

Page 8: ...eur soit à effleurement avec le plafond fini Clouer ou visser solidement le support en place Figure 3 www airkinglimited com A210572219 Rev D 12 12 8 of 12 2 Fixer par pression le bâti du ventilateur dans le support Figure 4 Le ventilateur peut être fixé par pression en position avec le collet de conduit faisant face à gauche ou à droite en fonction de quelle direction est la plus pratique SECTION...

Page 9: ...du ventilateur raccorder un fil blanc provenant de la maison aux deux fils blancs du réceptacle de la lumière et le fil blanc du réceptacle du ventilateur d évacuation Raccorder le fil noir provenant du commutateur mural aux deux fils noir du réceptacle de la lumière et au fil noir du réceptacle du ventilateur d évacuation Raccorder le fil de mise à la terre de la maison au fil vert du réceptacle ...

Page 10: ...ètement la grille avant de la réinstaller Pour réinstaller la grille vous référer à la Section 6 Complétion de l installation Nettoyage de l assemblage du ventilateur Débrancher le cordon du moteur de son réceptacle Nettoyer toutes les pièces avec un chiffon sec ou passer délicatement l aspirateur dans le ventilateur NE JAMAIS IMMERGER DES PIÈCES ÉLECTRIQUES DANS L EAU Rebrancher le cordon et reme...

Page 11: ... ET DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILITÉ EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA RÉPARATION DE TOUS FUSIBLES DISJONCTEURS OU RÉCEPTACLES DE MAISON MALGRÉ N IMPORTE QUOI À L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILITÉ D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE DÉPASSERA LE PRIX D ACHAT DU PRO...

Page 12: ...99054 3 1 Réceptacle du Moteur 5S2205004 4 1 Réceptacle de la Lumière 5S1201012 5 2 Clip 5S2205025 9 1 Couvercle des câbles 5S2205040 7 1 Roue de la Soufflante 5S2299004 8 1 Moteur BFQF50 5S2299011 Moteur BFQF70 5S2299012 9 1 Clip 5S2205029 10 1 Support du Moteur 5S2299003 11 1 Assemblée de grille 5S9205030 12 1 Lentille d éclairage 5S2205031 13 1 Lampe de 26 watts 5S9999010 1 2 3 4 5 6 7 8 9 10 1...