background image

M22 Moisture Co., Ltd. 

Tel.+886 3 3225829 –  Fax +886 3 3220433 

www.airguard.com.tw

 

 e-mail:[email protected] 

Wireless Transmitter Instruction

 

§

 

Wireless transmitter:

 

 

transmitter:Use DC 12V battery  
Receiving distance:In an open space without obstacles, the effective distance is about 50 meters. 
 

            The actual situation depends on the number of obstacles, and the conservative distance is 

about 10-25 meters. 

 

§

 

Wireless receiver: 

 

 
After the wireless receiver is tested, it will be fixed on the back panel of each AG-800 machine. Do 
not try to unplug it. 
 

Setting Function: 

1.

 

All receivers can receive any transmitter to complete the frequency comparison。 

2.

 

Each receiver can remember the signals of five groups of transmitters。 

3.

 

Each transmitter has been set up at the factory, and users can use it without resetting. The initial 
setting is to press the A button to start the machine, and press the B button to stop the 
machine. 

4.

 

4. If the user wants to control the machine through other transmitters (except the original 
equipped transmitter), the setting needs to be completed within 15 seconds of the machine 
being turned on, otherwise the machine will automatically leave the setting mode after 15 
seconds。 

 

Setting example:

 

There is an LED light on the control panel on the back of the machine. When the machine starts, the 

green LED light on the back of the AG-800 machine will flash for 15 seconds. 

Summary of Contents for AG-800

Page 1: ...M22 Moisture Co Ltd Tel 886 3 3225829 Fax 886 3 3220433 www airguard com tw e mail sales airguard com tw AG 800 User Manual English ...

Page 2: ...hine and the AC power outlet make sure the machine is turned off and not in use l When adding FLD 05 disinfectant please unplug the machine l Unplug the machine if it will not be used for a long time l This machine is for indoor use only Do not expose the machine to rain or humidity If liquid is spilled do not connect the machine to an AC power source and wipe it If any liquid gets into the machin...

Page 3: ...ase unplug it and stop working immediately Contact the dealer after packing the machine in the original carton l Before transporting the machine make sure that the fuel tank of the machine is completely empty l Disinfectant is inedible and swallowing disinfectant may cause health risks Store the disinfectant in a safe place indoors If you come into contact with the eyes or accidentally swallow it ...

Page 4: ...n effect but also cause machine blockage and damage Operation Do not overfill the tank when adding disinfectant solution and remember to tighten the cap After that please insert the power plug into the socket and turn on the power switch on the back of the machine Connect the machine to a power source Before connecting please confirm whether the required power indicated on the technical label of t...

Page 5: ...ransmitter to complete the frequency comparison 2 Each receiver can remember the signals of five groups of transmitters 3 Each transmitter has been set up at the factory and users can use it without resetting The initial setting is to press the A button to start the machine and press the B button to stop the machine 4 4 If the user wants to control the machine through other transmitters except the...

Page 6: ...mit a small amount of smoke 3 After spraying smoke all the sterilizers will temporarily stop themselves to prepare for repeated heating During this period of reheating the machine was unable to emit smoke 4 The AG 800 is equipped with an electronic flow detector When the remaining oil is insufficient the pump will stop automatically and the LED on the back will flash to indicate that the oil is in...

Page 7: ...ation Imput Voltage US model AC 100 120V 50 60 Hz 6 7A EU model AC 220 240V 50 60Hz 3 5A Power rated 800W Warm up time 2 min Consumption 10ml min Fluid tank capacity 0 8L Compatible fluid Air Guard FLD 05 Disinfectant Ambient temp range 0 40 Control Manual Wireless control Dimension L315 W128 H218 mm Weight 3 8 KG ...

Page 8: ...M22 Moisture Co Ltd Tel 886 3 3225829 Fax 886 3 3220433 www airguard com tw e mail sales airguard com tw C08AG8000 ...

Reviews: