T

EMPERTURE INCREASE ABOVE INCOMING WATER TEMPERATURE 

 
 
 
 

 
 
 
 
 
 

Figure 3 Wiring Connections

 

 
 

 

 
 
 
 

 

 

Microprocessor limits temperature increase according to the  
pre-selected 

temperature 

      

Figure 4  Potentiometer  Connection 

 
 

TROUBLE SHOOTING GUIDE: 

Your Instant-Temp water heater has no internal user serviceable parts and should be retuned to the factory for repair or replacement.  
Please contact factory for return authorization.  If after following the Installation Instructions, your Instant-Temp does not heat water 
in accordance with this literature, please check the following: 

1. 

Check flow rate – 

Controlling flow rate is essential to insure proper temperature rise.  All Standard Flow Models require. 1.0 GPM to 

activate and shut off t 0.65 GPM.  All Low Flow models require 0.5 GPM to activate. 

2. 

LED Indicator – 

If front panel LED does not illuminate check A/C breaker. 

3. Low 

Power – 

Make sure of your exact voltage by using a voltmeter.  You should obtain your reading off the two outside terminals located 

on the heater.  Compare this reading against the voltage specified in the Installation Instructions.  The center terminal is always the earth 
ground.

  

4. Low 

Voltage – 

The percentage of reduction in voltage will result in a like reduction in temperature rise.  

 

5. 

Low Amperage Draw – 

Check amperage draw using an Amperage probe.  Please compare your results with the Installation Instruction 

sheets (Table 1) to determine if the heater is operating correctly.  

6. 

Length of pipe 

– Length of pipe run will affect the temperature at the faucet.  The heater should be mounted no more than 12-18 inches 

from the point of use. 

7. 

Check Shut-Off Valve – 

Check shut-off valve and make sure valve is open 100% to allow full water pressure to heater.  Models require a 

minimum of 45 PSI. (Low pressure (LP) models require 20-45 PSI). 

8. 

Freezing 

– Instant-Temp heaters must be drained and stored if in a location subject to freezing.  Disconnect the inlet/outlet compression 

fittings and blow air through one side to the heater to assist draining.  Failure to completely remove water from the unit will result in 
freezing and cracking.  

9. Problems? – 

Call our toll-free hot line (800) 447-4962 or (310) 534-2300.

 

 

Exclusive 12-Month Warranty 

 

Your Instant-Temp water heater has been engineered and built to the highest quality standards and is backed by a full, factory 

warranty.  Every Instant-Temp water heater is guaranteed to be free from defects in material and workmanship for a period of one (1) year 
from the date of purchase.  The above warranty applies to original purchaser if unit is installed to Chronomite Laboratories, Inc.’s 
Installation Instructions.  Chronomite Laboratories, Inc. will repair or exchange parts at the factory at no cost.  This warranty is limited to 
repairing or replacing said products which prove to be defective upon factory inspection FOB Harbor City, CA.    

 

    Air Delights, Inc. 

  9974 SW Arctic Dr. 

 Beaverton, Or. 97005 

 

Toll Free Technical Hotline:  (800) 440-5556 Telephone:  (503) 352-1201 

Fax:  (503) 643-8224 

I-919-Rev.5 -03/05                                                                          www.airdelights.com

MODEL 

VAC 

0.5GPM 

1.0 GPM 

1.5 GPM 

2.0GPM 

E-30 208 41

°°°°

F 21

°°°°

F 14

°°°°

F 10

°°°°

E-30 220-240 41

°°°°

F 21

°°°°

F 14

°°°°

F 10

°°°°

E-30 277 41

°°°°

F 21

°°°°

F 14

°°°°

F 10

°°°°

E-46 208 63

°°°°

F 31

°°°°

F 21

°°°°

F 16

°°°°

E-46 220-240 63

°°°°

31ºF 

21

°°°°

F 16

°°°°

E-46 277 63

°°°°

F 31

°°°°

F 21

°°°°

F 16

°°°°

E-60 208 82

°°°°

F 41

°°°°

F 27

°°°°

F 20

°°°°

E-60 220-240 82

°°°°

F 41

°°°°

F 27

°°°°

F 20

°°°°

E-60 277 82

°°°°

F 41

°°°°

F 27

°°°°

F 20

°°°°

E-70 208 95º 

48

°°°°

F 32

°°°°

F 24

°°°°

E-70 220-240 95

°°°°

48ºF 

32

°°°°

F 24

°°°°

E-70 277 95

°°°°

F 48

°°°°

F 32

°°°°

F 24

°°°°

E-80 208 

109

°°°°

F 54

°°°°

F 36

°°°°

F 27

°°°°

E-80 220-240 

109

°°°°

F 54

°°°°

F 36

°°°°

F 27

°°°°

E-80 277 

109

°°°°

F 54

°°°°

F 36

°°°°

F 27

°°°°

E-90 220-240 

122

°°°°

F 61

°°°°

F 41

°°°°

F 31

°°°°

E-90 277 

122

°°°°

F 61

°°°°

F 41

°°°°

F 31

°°°°

Summary of Contents for E-30

Page 1: ...ous electrical shocks B Turn off water supply 1 Remove heater cover Attach conduit to the conduit through electrical access hole Then feed wires Do not attach wiring yet 2 Mount unit horizontally against the wall so label reads correctly See Fig 1 Mount with four screws through the mounting holes located on the base plate housing using molly anchors or fasteners CAUTION Heating elements may burn o...

Page 2: ...ox 3 3 Electrical conduit 1 conduit length as required 4 4 Dual outlet angle valve 1 female Pipe x 7 16 comp x 3 8 comp x Brass Craft PN R2701R RGH or equivalent 5 5 Compression fittings supplied 2 3 8 compression fittings x Male Pipe 6 6 Copper or flex tubing 1 3 8 OD 5 long keep short 7 7 Copper or flex tubing 1 3 8 OD length as required keep short 8 A 212 9 8 Faucet Flow Control Dual Thread 9 P...

Page 3: ...2 Male Female 0 5 FLOW CONTROL SPECIFICATIONS FIGURE 2 Material Chrome plated brass housing FLOW CONTROL INSTALLATION Threading MODEL A212 and L212 have Male outside threads for See Parts List 8 faucets with 15 16 Female threads and 55 64 Male threads Flow controls are adaptable to other thread configurations Please call factory if an adapter is needed Potentiometer Optional Field Temperature Cont...

Page 4: ...water pressure to heater Models require a minimum of 45 PSI Low pressure LP models require 20 45 PSI 8 Freezing Instant Temp heaters must be drained and stored if in a location subject to freezing Disconnect the inlet outlet compression fittings and blow air through one side to the heater to assist draining Failure to completely remove water from the unit will result in freezing and cracking 9 Pro...

Reviews: