![Air-Care FG0193 Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/air-care/fg0193/fg0193_operating-instructions-manual_2875756006.webp)
Page 6 of 12
After cleaning each duct, each opening should then be decontaminated by fogging with our EPA
registered Envirocon sanitizer, Soot Set sealer and Liquid Odor Kill deodorizer.
Brush Motor Replacement Kit
Updated Coaxial Spring Mount
The Brush Motor and Mount retains all the advantages of the original and includes some
improvements to reliability, durability, and Debris Collection.
This motor and Hose mount will replace all previous motors and mounts.
KEEP THE NEW MOTOR FULLY ASSEMBLED!
First remove the OLD motor and motor mount from your hose:
1. Remove the screws holding the metal collar on the end of the hose and save the screws and
nuts to mount the new motor and mount.
2. Cut the 3 wires for the motor leaving enough cord to crimp (or solder) the wires to the new
motor wires. All 3 wires will need to be the same length for this new Motor Connection.
3. You will no longer need any of the parts in the original motor assembly unless you are
returning it to Air-Care with an RMA for warranty evaluation.
Installing the NEW motor assembly.
1. Be sure you have all the parts for the installation.
a. Your original Screws, 10-
32 x 5/8” long machine screws,
b. 10-32 Hex Nuts with built in Lock Washers.
2. Remove the outer insulation from the black power cord in the hose to expose the 3
insulated motor wires about 2 inches long.
3.
Strip the insulation off of all 3 wires about ½” back from the ends.
4. Slide the black Shrink Tubing over the cable. It will be slid over the new connections after
the wires are connected.
5. Slide the 3 pieces of shrink tubing over each of the motor wires. The connections can be
made by crimping the new connectors or soldering them. If you are planning to solder the
connections, be sure the blue shrink tubing is far enough away from the heated ends to
prevent it from shrinking prematurely.