Aiphone RX-JA Instructions Download Page 1

- INSTRUCTIONS -

WIRING DIAGRAM:

RX-JA

Flush Mounted Door Station for the RAX/RCX Systems

Special
Order
Products

1
2
3
4

RA-B

RAX or RCX

CEU

1
2
3
4

1
2
3
4

1
2
3
4

NOTES:

1.In this example the RX-JA is shown connected
to station 10. Any open station number can be
used.
2. When the call button is pressed on the RX-JA
the external bell will activate, alerting internal
master stations that there is a call from the
door.
3. Any master station can call the RX-JA.
4.Only wiring concerning the RX-JA is shown
here.  For complete installation and wiring
information, please refer to the standard RAX/
RCX instructions.

The RX-JA is a weather resistant door station for use with the RAX or RCX Microprocessor-
based intercom system.

#10

#11

#12

1
2
3
4

RA-D

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA  98005
(425) 455-0510
FAX (425) 455-0071

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

TOLL FREE FAX LINE:

(800) 832-3765

E-MAIL: [email protected]

RX-JA Instr.

 1198bkjd

RX-JA

1
2
3
4

BELL

To Power

for Bell

BLACK

SPECIFICATIONS:

Power Source:

Supplied by master station

Call Button:

Single pole, single throw, normally open

Call Annunciation:

Pressing call button at sub activates external device

Call Button Contacts:

24V DC, 1A (Max.)

Mounting:

2-gang electrical box

Wiring:

2 twisted pair homerun to RAX/RCX CEU,
plus 2 wires to external signaling device.
Use Aiphone #832204  for homerun wiring,
#812202 for bell connection.

Wiring Distance:

RAX: 2,000' with 22AWG
RCX: 6,500' with 22AWG

Dimensions (H x W x D): 4-1/2" x 4-9/16" x 3/8" (outer depth)

NOTE:

Call-in signal from RX-JA will
not be heard at the master
stations. An external doorbell or
sounding device must be used.