background image

1A1

1A2

+

L

L

DC18V

RLSE.

DOOR1

2A1

2A2

DOOR2

6PIN CONNECT OR WIRING DIAGRAM

for MK-2MCD & MK-1GD

RY-3DL

EL-9S

AC Trans.

L1

C1

L2

C2

L3

C3

b1

b2

b3

D1

D2

E

EL-9S

MK-DBC

Master

MK-2MCD

Sub

MK-2HCD

2

4

4

PS18

MK-DGC

2

PS24

: PS-1820DIN, PS-1820S, PS-1820UL (2A)

RY-3DL

EL-9S

EL-9S

5

PT

MAW-B

Sub

MK-2HCD

WHITE

RED(+)

BLACK(–)

ORANGE
ORANGE

Light

VIDEO +
VIDEO–

MONITOR

TV (75 ohm)

PS18

L

Local switch

MAW-B

PS24

MONITOR

TV (75 ohm)

2 Master

MK-2MCD

B1
B2

SUB

PS24

PS18

: 24V DC power supply for MAW-B or Relay
  locally available.

+

(MK-2HCD)

(MK-DGC 1 ) 

(MK-DGC 2 )

YELLOW
ORANGE

3

MK-D

2

Light

2

2

BLUE

WHITE

GRAY

GRAY

(MK-2HCD)

NOTE: YELLOW & ORANGE wire provides selective door release control 

with RY-3DL adaptor. Works for MK-2MCD only.

NTSC

Contact rating:

0.5A (DC 30V. AC 125V)