Aiphone LEM-1 Installation And Operation Manual Download Page 2

– 2 –

CAUTION

LEM equipment, except for LE-D or LE-DA, is designed for indoor use only. 
Do not install outdoors.

LEM is an electrical device, which must not be exposed to water or any other liquid.

Do not connect AC wires to any terminal on any unit.

Do not connect any power source other than specified to ter, – on LEM. 
Doing so can cause fire or damage the unit.

Unplug power supply while making any wire terminations.

Do not install LEM equipment in any of the following locations, as it may cause the system to malfunction;

– High or extreme cold temperature areas: under direct sunlight, near equipment that varies in temperature, in

front of air-conditioner, inside a refrigerated area, etc.

– Places subject to moisture or humidity extremes,
– Places subject to environmental conditions, such as oil, dust, chemicals, salt, etc.
– Places subject to constant vibration or impact.

IMPORTANT

–Observe the following to prevent fire, injury to people, malfunction, or damage to the equipment.

Do not open the LEM equipment except for wiring. Ask qualified personnel.

Do not change or modify LEM.

Keep moisture away from unit and AC cord.

Keep all DC wiring at least 30cm, 20” away from AC wiring, fluorescent lighting, or dimmer switches.  Cross AC wiring
at a 90° angle.

Keep AC cord (power supply) and DC wiring from being pulled or crushed.

LEM is not operable during a power failure.

In areas where broadcasting station antennas are close by, intercom system may be affected by radio frequency
interference.

Make sure wires are connected properly before plugging in DC power supply.

Severe weather conditions, such as lightning storms, may cause damage to LEM equipment. We recommend that
power surge protection be installed as follows: (However, this does not guarantee that no damage will occur.

Before actually mounting the LEM equipment, the contents of this Manual must be 

t

horoughly read and understood.

+, – 

:

6V DC power supply

E

:

Common communication

1 ~ 3

: Sub 1 ~ 3 calling and communication

Install a surge-arrester( discharging 
voltage: 100

180V) at a point 

close to the output, taken to earth 
ground.

Grounded

Surge-arrester
(Aiphone model:SA-1)

PS-6D or SKK-620

LEM

6V DC

Red (+)

White or Black(-)

-

+

3

3

PRECAUTIONS ON INSTALLATION & WIRING

• If the power supply has a GROUND

terminal, take it to an earth ground.
In this case, a separate surge
arrester is not necessary.

• When using a power supply that

has no GROUND terminal, install a
surge arrester near the output as
shown.

4

4

4

4

WIRING

LEM-1

LEM-3

Actual terminal locations

E

1

+

E

1

2

3

+